4.7 Article

Optimizing Volumetric Efficiency and Backscatter Communication in Biosensing Ultrasonic Implants

Journal

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS
Volume 14, Issue 6, Pages 1381-1392

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBCAS.2020.3033488

Keywords

Implants; Backscatter; Modulation; Acoustics; Resonant frequency; Impedance; Uplink; Backscatter; circuit model; echo modulation; implant; modulator; piezoelectric; ultrasound; wireless

Funding

  1. Hellman Fellows Fund

Ask authors/readers for more resources

Ultrasonic backscatter communication has gained popularity in recent years with the advent of deep-tissue sub-mm scale biosensing implants in which piezoceramic (piezo) resonators are used as acoustic antennas. Miniaturization is a key design goal for such implants to reduce tissue displacement and enable minimally invasive implantation techniques. Here, we provide a systematic design approach for the implant piezo geometry and operation frequency to minimize the overall volume of the implant. Optimal geometry of the implant piezo for backscatter communication is discussed and contrasted with that of power harvesting. A critical design aspect of an ultrasonic backscatter communication link is the response of the piezo acoustic reflection coefficient Gamma with respect to the variable shunt impedance, Z(E), of the implant uplink modulator. Due to the complexity of the piezo governing equations and multi-domain, electro-acoustical nature of the piezo, Gamma(Z(E)) has often been characterized numerically and the implant uplink modulator has been designed empirically resulting in sub-optimal performance in terms of data rate and linearity. Here, we present a SPICE friendly end-to-end equivalent circuit model of the channel as a piezo-IC co-simulation tool that incorporates inherent path losses present in a typical ultrasonic backscatter channel. To provide further insight into the channel response, we present experimentally validated closed form expressions for Gamma(Z(E)) under various boundary conditions. These expressions couple Gamma to the commonly used Thevenin equivalent circuit model of the piezo, facilitating systematic design and synthesis of ultrasonic backscatter uplink modulators.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available