Femoral diameter and stem type are independent risk factors for ARMD in the Large-headed ASR THR group
Published 2015 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Femoral diameter and stem type are independent risk factors for ARMD in the Large-headed ASR THR group
Authors
Keywords
Metal-on-metal, Pseudotumour, Revision, Total hip replacement, ARMD, Cox regression, Risk factors
Journal
BMC MUSCULOSKELETAL DISORDERS
Volume 16, Issue 1, Pages -
Publisher
Springer Nature
Online
2015-05-14
DOI
10.1186/s12891-015-0566-6
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- High Prevalence of Adverse Reactions to Metal Debris in Small-headed ASR™ Hips
- (2013) Aleksi Reito et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography
- (2013) Anna Panagiotidou et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Taper junction failure in large-diameter metal-on-metal bearings
- (2013) D. J. Langton et al. Bone & Joint Research
- Corrosion at the Cone/Taper Interface Leads to Failure of Large-diameter Metal-on-metal Total Hip Arthroplasties
- (2012) Heiko Meyer et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Large Diameter Metal on Metal Articulations. Comparison of Total Hip Arthroplasty and Hip Resurfacing Arthroplasty
- (2012) Christopher M. Jack et al. JOURNAL OF ARTHROPLASTY
- Pseudotumors in Association with Well-Functioning Metal-on-Metal Hip Prostheses
- (2012) Alister J Hart et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement
- (2012) B. H. Bosker et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- The ten-year survival of the Birmingham hip resurfacing
- (2012) D. W. Murray et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Birmingham hip resurfacing at a mean of ten years
- (2012) G. Coulter et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Failure rates of metal-on-metal hip resurfacings: analysis of data from the National Joint Registry for England and Wales
- (2012) Alison J Smith et al. LANCET
- Edge loading in metal-on-metal hips: low clearance is a new risk factor
- (2012) Richard J Underwood et al. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE
- Statistical analysis of arthroplasty data
- (2011) Jonas Ranstam et al. Acta Orthopaedica
- A comparison of explanted Articular Surface Replacement and Birmingham Hip Resurfacing components
- (2011) R. Underwood et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- High failure rates with a large-diameter hybrid metal-on-metal total hip replacement
- (2011) B. J. R. F. Bolland et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Accelerating failure rate of the ASR total hip replacement
- (2011) D. J. Langton et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Reduced Articular Surface of One-piece Cups: A Cause of Runaway Wear and Early Failure
- (2010) William L. Griffin et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement
- (2010) D. J. Langton et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Risk factors for inflammatory pseudotumour formation following hip resurfacing
- (2009) S. Glyn-Jones et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Early clinical failure of the Birmingham metal-on-metal hip resurfacing is associated with metallosis and soft-tissue necrosis
- (2009) B. Ollivere et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
Add your recorded webinar
Do you already have a recorded webinar? Grow your audience and get more views by easily listing your recording on Peeref.
Upload NowCreate your own webinar
Interested in hosting your own webinar? Check the schedule and propose your idea to the Peeref Content Team.
Create Now