4.5 Article

A meta-analysis of ventriculostomy-associated cerebrospinal fluid infections

Journal

BMC INFECTIOUS DISEASES
Volume 15, Issue -, Pages -

Publisher

BMC
DOI: 10.1186/s12879-014-0712-z

Keywords

Cerebral ventriculitis; Cerebrospinal fluid; Ventriculostomy; Catheter-related infection; Neurosurgery; Meta-analysis

Ask authors/readers for more resources

Background: Ventriculostomy insertion is a common neurosurgical intervention and can be complicated by ventriculostomy-associated cerebrospinal fluid infection (VAI) which is associated with increased morbidity and mortality. This meta-analysis was aimed at determining the pooled incidence rate (number per 1000 catheter-days) of VAI. Methods: Relevant studies were identified from MEDLINE and EMBASE and from reference searching of included studies and recent review articles on relevant topics. The Newcastle-Ottawa Scale was used to assess quality and risk of bias. A random effects model was used to pool individual study estimates and 95% confidence intervals (CI) were calculated using the exact Poisson method. Heterogeneity was assessed using the heterogeneity x(2) and I-squared tests. Subgroup analyses were performed and a funnel plot constructed to assess publication bias. Results: There were a total of 35 studies which yielded 752 infections from 66,706 catheter-days of observation. The overall pooled incidence rate of VAI was 11.4 per 1000 catheter days (95% CI 9.3 to 13.5), for high quality studies the rate was 10.6 (95% CI 8.3 to 13) and 13.5 (95% CI 8.9 to 18.1) for low quality studies. Studies which had mean duration of EVD treatment of less than 7 days had a pooled VAI rate of 19.6 per 1000 catheter-days, those with mean duration of 7-10 days had VAI rate of 12.8 per 1000 catheter-days and those with mean duration greater than 10 days had VAI rate of 8 per 1000 catheter-days. There was significant heterogeneity for the primary outcome (p = 0.004, I-squared = 44%) and most subgroups. The funnel plot did not show evidence for publication bias. Conclusions: The incidence rate of VAI is 11.4 per 1000 catheter-days. Further research should focus on analysis of risk factors for VAI and techniques for reducing the rate of VAI.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available