4.4 Article

A Sensitive Fluorescent Assay for Tetracycline Detection Based on Triple-helix Aptamer Probe and Cyclodextrin Supramolecular Inclusion

Journal

JOURNAL OF FLUORESCENCE
Volume 31, Issue 1, Pages 63-71

Publisher

SPRINGER/PLENUM PUBLISHERS
DOI: 10.1007/s10895-020-02631-x

Keywords

Tetracycline; Fluorescent; Biosensor; gamma-cyclodextrin; Triple-helix aptamer probe

Funding

  1. Hunan Provincial Natural Science Foundation of China [2018JJ3869]
  2. Training Program for Excellent Young Innovators of Changsha [kq1802021]

Ask authors/readers for more resources

An effective pyrene excimer signaled fluorescent biosensor for the determination of tetracycline was developed based on triple-helix aptamer probe (TAP) and supramolecular inclusion of cyclodextrin. The biosensor showed high sensitivity and specificity in detecting the target molecule, offering a simple and cost-effective protocol.
Herein, an effective pyrene excimer signaled fluorescent biosensor for the determination of tetracycline based on triple-helix aptamer probe (TAP) and supramolecular inclusion of cyclodextrin was reported. The TAP was devised containing an aptamer loop, two DNA segment stems and a triplex-forming oligonucleotide (signal probe) labeled with pyrenes at 5 ' and 3 ' ends. The presence of target could result in its binding towards aptamer with a mighty affinity, leading to a conformation change of the TAP and whereupon the release of the signal probe. This liberty of signal probe enabled the formation of pyrene excimer, generating fluorescence signals. Further, signal amplification was fulfilled through the addition of gamma-cyclodextrin which could interact with pyrene dimer, thus leading to an enhanced on-state of the sensing ensemble. In contrast, when the target was absent, the sensing ensemble remained off-state because of the long distance between two pyrene molecules. When the conditions were properly optimized, the increasing signal kept a linear dependence on target concentrations ranging from 5.0 nM to 100 nM, and the detection limit reached as low as 1.6 nM. In this way, a newly-constructed, simple, and economically affordable protocol enjoys desirable efficiency, sensitivity, specificity in biosensing. Also, its universality as another attractive behalf in assaying diverse targets was envisioned with only the need of matched aptamer replacement.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available