4.5 Article

Assessment of gingival thickness using digital file superimposition versus direct clinical measurements

Journal

CLINICAL ORAL INVESTIGATIONS
Volume 25, Issue 4, Pages 2353-2361

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00784-020-03558-0

Keywords

Phenotype; Gingiva; Radiology; 3-D imaging

Funding

  1. Department of Periodontics Graduate Student Research Fund, University of Iowa College of Dentistry

Ask authors/readers for more resources

The study demonstrated that digital measurement of gingival thickness is comparable with direct clinical assessments performed with transgingival horizontal probing using an endodontic spreader.
Objectives This study was aimed at evaluating the correlation and reproducibility of gingival thickness quantification using digital and direct clinical assessment methods. Materials and methods Patients in need of tooth extraction were allocated into two groups according to the gingival thickness measurement method, either using an endodontic spreader (pre-extraction) or a spring caliper (post-extraction), both on the mid-facial (FGT) and mid-lingual (LGT). Pre-extraction Digital Imaging and COmmunications in Medicine (DICOM) and STereoLithography (STL) files of the arch of interest were obtained and merged for corresponding digital measurements. Inter-rater reliability between digital and direct assessment methods was analyzed using inter-class correlation coefficients (ICC). Results Excellent inter-rater reliability agreement was demonstrated for all parameters. Comparison between the endodontic spreader and the digital method revealed excellent agreement, with ICC of 0.79 (95% CI 0.55, 0.91) for FGT and 0.87 (95% CI 0.69, 0.94) for LGT, and mean differences of 0.08 (- 0.04 to 0.55) and 0.25 (- 0.30 to 0.81) mm for FGT and LGT, respectively. Meanwhile, the comparison between the caliper and the digital method demonstrated poor agreement, with ICC of 0.38 (95% CI - 0.06, 0.70) for FGT and 0.45 (95% CI - 0.02, 0.74) for LGT, and mean differences of 0.65 (0.14 to 1.16) and 0.64 (0.12 to 1.17) mm for FGT and LGT, respectively. Conclusions Digital measurement of gingival thickness is comparable with direct clinical assessments performed with transgingival horizontal probing using an endodontic spreader.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available