4.5 Article

Cytocompatibility of calcium silicate-based sealers in a three-dimensional cell culture model

Journal

CLINICAL ORAL INVESTIGATIONS
Volume 21, Issue 5, Pages 1531-1536

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00784-016-1918-9

Keywords

Cytotoxicity; Calcium silicate-based materials; Root canal sealer

Funding

  1. FAPERJ, Rio de Janeiro, Brazil
  2. FAPERJ [E-26/010.001243/2015]

Ask authors/readers for more resources

The aim of the present study was to evaluate cytotoxic effects and cytokine production of calcium silicate-based sealers (EndoSeal, EndoSequence BC Sealer, and MTA Fillapex) using an in vitro root canal filling model and three-dimensional (3D) cell culture. AH Plus as a reference was compared to contemporary calcium silicate cements regarding cell viability and cytokine production. Root canals of 30 human maxillary incisors were prepared using a single-file reciprocating technique. The samples were randomly distributed and canals filled with either AH Plus, EndoSeal, EndoSequence BC Sealer, and MTA Fillapex (n = 6). In the negative control group, the root canal remained unfilled. Sealers were placed into the canals along with a gutta-percha cone placed to working length. Balb/c 3T3 fibroblasts, cultured in a type I collagen 3D scaffold, were exposed to filling material and the respective root apex for 24 h. Cytocompatibility of the materials was evaluated using the methyl-thiazoldiphenyl-tetrazolium (MTT) assay. The production of IL-1 beta, IL-6, and IL-8 was analyzed using enzyme-linked immunosorbent assay (ELISA). One-way analysis of variance was performed, and when the F-ratios were significant, data were compared by Duncan's multiple-range test. The alpha-type error was set at 0.05. EndoSeal, Endosequence BC Sealer and AH Plus showed cell viability that was similar to the negative control group (P > 0.05), while MTA Fillapex sealer was cytotoxic (P < 0.05). Varying production of IL-1 beta, IL-6, and IL-8 was detected in all samples. In an in vitro root canal filling model with 3D cell culture, AH Plus, EndoSeal, and EndoSequence BC Sealer were cytocompatible. These results may suggest that AH Plus, EndoSeal and EndoSequence BC Sealer may achieve better biological response when compared to MTA Fillapex.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available