4.7 Article

Preliminary investigation of the use of Raman spectroscopy to predict beef spoilage in different types of packaging

Journal

MEAT SCIENCE
Volume 165, Issue -, Pages -

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.meatsci.2020.108136

Keywords

Beef; Raman spectroscopy; Packaging; Spoilage

Funding

  1. project Key R&D Program of Shandong province [2018GGX108004]
  2. earmarked fund for China Agriculture Research System [CARS-37]
  3. Special fund for innovation team of modern agricultural industrial technology system in Shandong Province [SDAIT-09-09]
  4. funds of Shandong Double Tops Program [SYL2017XTTD12]

Ask authors/readers for more resources

In this study, pH, meat color analysis, microbial counts and Raman spectroscopic data were obtained from beef steaks stored at 4 degrees C for up to 21 days using two different packaging methods: vacuum (VP) and modified atmosphere packaging (MAP). Models using partial least square regression (PLSR), indicated that Raman spectroscopy was able to predict total viable counts (TVC) and lactic acid bacteria (LAB) measured at 21d post mortem (TVC in VP: R-cv(2) = 0.99, RMSEP = 0.61; TVC in MAP: R-cv(2) = 0.90, RMSEP = 0.38; LAB in VP: R-cv(2) = 0.99, RMSEP = 0.54; LAB in MAP: R-cv(2) = 0.75, RMSEP = 0.60). The results of this study demonstrate that Raman spectroscopy may have potential for the rapid determination of meat spoilage.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available