The first study comparing a wearable watch‐type blood pressure monitor with a conventional ambulatory blood pressure monitor on in‐office and out‐of‐office settings
Published 2020 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
The first study comparing a wearable watch‐type blood pressure monitor with a conventional ambulatory blood pressure monitor on in‐office and out‐of‐office settings
Authors
Keywords
-
Journal
Journal of Clinical Hypertension
Volume 22, Issue 2, Pages 135-141
Publisher
Wiley
Online
2020-01-20
DOI
10.1111/jch.13799
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- The further development of out-of-office BP monitoring: Japan's ImPACT Program Project's achievements, impact, and direction
- (2019) Kazuomi Kario et al. Journal of Clinical Hypertension
- Validation of two watch-type wearable blood pressure monitors according to the ANSI/AAMI/ISO81060-2:2013 guidelines: Omron HEM-6410T-ZM and HEM-6410T-ZL
- (2019) Mitsuo Kuwabara et al. Journal of Clinical Hypertension
- Nighttime Blood Pressure Measured by Home Blood Pressure Monitoring as an Independent Predictor of Cardiovascular Events in General Practice
- (2019) Kazuomi Kario et al. HYPERTENSION
- The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
- (2019) Satoshi Umemura et al. HYPERTENSION RESEARCH
- Expert panel consensus recommendations for ambulatory blood pressure monitoring in Asia: The HOPE Asia Network
- (2019) Kazuomi Kario et al. Journal of Clinical Hypertension
- Nocturnal Hypertension
- (2018) Kazuomi Kario HYPERTENSION
- Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality
- (2018) José R. Banegas et al. NEW ENGLAND JOURNAL OF MEDICINE
- 2018 ESC/ESH Guidelines for the management of arterial hypertension
- (2018) Bryan Williams et al. EUROPEAN HEART JOURNAL
- Validation of the TM-2441 ambulatory blood pressure measurement device according to the ISO 81060-2
- (2018) Kazuomi Kario et al. BLOOD PRESSURE MONITORING
- 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines
- (2017) Paul K. Whelton et al. HYPERTENSION
- A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation
- (2017) N Boubouchairopoulou et al. JOURNAL OF HUMAN HYPERTENSION
- Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
- (2015) Grzegorz Bilo et al. BLOOD PRESSURE MONITORING
- Sleep Blood Pressure Self-Measured at Home as a Novel Determinant of Organ Damage: Japan Morning Surge Home Blood Pressure (J-HOP) Study
- (2015) Kazuomi Kario et al. Journal of Clinical Hypertension
- Comparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use
- (2012) Takahiro Komori et al. BLOOD PRESSURE MONITORING
- Nighttime Home Blood Pressure and the Risk of Hypertensive Target Organ Damage
- (2012) Joji Ishikawa et al. HYPERTENSION
- Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
- (2011) Heiko Gesche et al. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY
Find Funding. Review Successful Grants.
Explore over 25,000 new funding opportunities and over 6,000,000 successful grants.
ExploreDiscover Peeref hubs
Discuss science. Find collaborators. Network.
Join a conversation