Journal
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
Volume 45, Issue 49, Pages 26059-26069Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2020.01.136
Keywords
Fuzzy logic; PID; Fuzzy-PID; On/off control; Hydroxy dry cell
Categories
Ask authors/readers for more resources
When the standard operating temperatures are exceeded in hydroxy generators, production performance decreases and power consumption increases. Self-adaptive fuzzy proportional integral derivative systems have been used to prevent this situation and to maintain optimum production conditions. The Fuzzy Logic is provided to tune the optimum PID parameters by using a gain scheduling method. The tuning scheme is demonstrated by a fuzzy decision process, which consists of fuzzification, knowledge and rule base, inference and defuzzification. Results of developed fuzzy proportional integral derivative (FPID), on-off, conventional PID and fuzzy control approach are discussed and compared. The presented result shows that self-adaptive fuzzy PID controllers achieve better control performance than conventional control methods mentioned. The last but not the least, developed approach minimizes the expertise needed to apply pulse width modulation technique. (C) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available