4.7 Article

Highly sensitive microfluidic detection of carcinoembryonic antigen via a synergetic fluorescence enhancement strategy based on the micro/nanostructure optimization of ZnO nanorod arrays and in situ ZIF-8 coating

Journal

CHEMICAL ENGINEERING JOURNAL
Volume 383, Issue -, Pages -

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.cej.2019.123230

Keywords

Carcinoembryonic antigen; Fluorescence detection; ZnO nanorod arrays; ZIF-8 coating; Microfluidic; Fluorescence enhancement

Funding

  1. National Natural Science Foundation of China [81572999, 81771839, 81773272, 81972886, 81874479, 51873033]
  2. Medical-Engineering Joint Funds from Shanghai Jiao Tong University [YG2017QN43]
  3. Shanghai Municipal Commission of Health and Family Planning [20174Y0123]
  4. Shanghai Natural Science Foundation [15ZR1401200]
  5. Program of Shanghai Academic Research Leader [16XD1400100]
  6. Science and Technology Commission of Shanghai Municipality [16JC1400700]
  7. Innovation Program of Shanghai Municipal Education Commission [2017-01-07-00-03-E00055]
  8. Program of Introducing Talents of Discipline to Universities [111-2-04]

Ask authors/readers for more resources

In this work, a synergetic fluorescence enhancement strategy based on micro/nanostructure optimization of ZnO nanorod arrays and in situ ZIF-8 coating was proposed for the highly sensitive microfluidic detection of carcinoembryonic antigen (CEA). The glass capillary was chosen as the microfluidic channel, and controllable construction of ZnO nanorod arrays on the inner wall of the microchannel was conducted via the intermittent reaction method. Additionally, the application of the optimal ZnO nanorod array to glass capillary-based microfluidic fluorescence detection was demonstrated. The fluorescence enhancement characteristic of the zeolitic imidazolate framework-8 (ZIF-8) towards organic fluorescence labels were investigated and successfully applied to protein marker detection. After formation of sandwich immunoassay on the ZnO/PAA nanorod arrays, the in situ ZIF-8 coating via a moderate chemical method could significantly improve the fluorescence intensity of fluorescent labels via direct contact. In CEA detection, the limit of detection (LOD) reached as low as 0.01 pg mL(-1), and the dynamic range was 0.01 pg mL(-1) to 100 pg mL(-1). Hence, the microfluidic fluorescence detection strategy based on the ZnO nanorod arrays/PAA layers/ZIF-8 coating with a synergetic fluorescence enhancement effect provides a superior, promising, and highly sensitive approach for the detection of protein markers, including CEA.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available