4.8 Article

Self-Polymerized Dopamine-Decorated Au NPs and Coordinated with Fe-MOF as a Dual Binding Sites and Dual Signal-Amplifying Electrochemical Aptasensor for the Detection of CEA

Journal

ACS APPLIED MATERIALS & INTERFACES
Volume 12, Issue 5, Pages 5500-5510

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acsami.9b19161

Keywords

carcinoembryonic antigen; electrochemical aptasensor; Au@PDA@Fe-MOF; dual binding sites; dual signal amplifying

Funding

  1. National Natural Science Foundation of China [81872835, 21872020, 21621003]
  2. Ministry of Science and Technology [2017YFC0906902, 2017ZX09301032]
  3. China Scholarship Council [201806085012]

Ask authors/readers for more resources

Fabrication of functional electrochemical biosensor is a hot topic; however, precise and sensitive cancer detection in early clinical diagnosis is still a great challenge. Continuous efforts have been devoted to explore functional materials for this issue. In this work, we developed a dual binding sites and dual signal amplifying electrochemical aptasensor of self-polymerized dopamine-decorated Au and coordinated with Fe-MOF (Au@PDA@Fe-MOF) for the detection of carcinoembryonic antigen (CEA). Remarkably, Au@PDA@Fe-MOF features high sensitivity, multiple active sites, good biocompatibility, and excellent selectivity, which is attributed to abundant -COOH in porous Fe-MOF and unsaturated Fe3+ sites on the surface of Fe-MOF as the active binding sites grafting more NH2-functionalized CEA-specific aptamer and redox PDA and Fe-MOF accelerating the movement of electrons for dual signal amplifying. Meanwhile, the electrochemical aptasensor shows favorable repeatability with 1.82% relative standard deviation (RSD) under five independent aptasensors and strong stability with only 3.3% degradation after 12 days of storage. In addition, the aptasensor has wide CEA detection range from 1 fg mL(-1) to 1 mu g mL(-1) with a low detection limit of 0.33 fg mL(-1) (S/N = 3). Furthermore, the aptasensor is feasible for accurate and quantitative detection of CEA in serum samples with RSD below 2.32%. The satisfying results demonstrate promising applications of the CEA aptasensor in practical sample analysis and lay an important foundation for other biomarker

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available