4.6 Article

Development and validation of a high performance liquid chromatography-tandem mass spectrometry method for the absolute analysis of 17 α D-amino acids in cooked meals

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1611, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.chroma.2019.460598

Keywords

Chiral derivatizing agent; D-amino acids; Enantioseparation; LC-MS/MS; Food samples; Cooked meals

Funding

  1. Spanish Ministry of Science, Innovation and Universities MICINN [RTI2018-095166-B-I00 C]
  2. Spanish Ministry of Education, Culture and Sport [FPU 15/03032, EST16/00831]
  3. NIHR Career Development Research Fellowship [NIHR-CDF-2017-10-032]
  4. Royal Society of Chemistry Tom West Fellowship [TWAF15/02]

Ask authors/readers for more resources

In the nutrition field, there is a lack of understanding about the impact that dietary chiral composition may have on health, especially regarding cooked meals. Chiral amino acids (AAs) are naturally present in food and their proportion may vary quite a lot. Besides, the D-amino acids (D-AAs) are present in very low concentration compared to L-AAs, so very sensitive methods are required for their accurate quantitation. Moreover, some of them have been described as indicators of quality and different food processes. In this research, we propose a robust method for the absolute quantitation and enantiomeric ratio of 17 D-AA5 in cooked meals. The Ms were extracted from 1 g of the homogenised meal with methanol, derivatised with (S)-N-(4-nitrophenoxycarbonyl) phenylalanine methoxyethyl ester ((S)-NIFE) and analysed by RP-LC-MS/MS. The separation was carried out with an Acquity BEH C18 (100 mm x 2.1 mm, 1.7 mu m) column at 70 degrees C, with 10 mmol/L ammonium bicarbonate in water as eluent A and acetonitrile as eluent B at a 0.3 ml.,/min flow rate in gradient elution. The MS operated in positive electrospray ionisation method in multiple reaction monitoring (MRM) mode. Isotopically labelled AAs were used as internal standards for the quantitation. The method was validated for 17 D-AAs in the cooked food samples in terms of specificity, linearity, precision, accuracy, matrix effect and stability. LLOQ are 2.0 ng/mL for most of them. Additionally, linearity was also studied for L-AAs. After optimization and validation, the method was applied to real breakfast, lunch and dinner samples of cooked meals (n= 18) that were part of a diet with a very high concordance with WHO dietary guidelines. Level of concentration of major and minor D-Ms have been described per total daily intake and within each of the three main meals. This method can be used for quality control purposes as well as to investigate the role of chiral composition in food and clinical outcomes. (C) 2019 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available