4.5 Article

ANN-based robust DC fault protection algorithm for MMC high-voltage direct current grids

Journal

IET RENEWABLE POWER GENERATION
Volume 14, Issue 2, Pages 199-210

Publisher

INST ENGINEERING TECHNOLOGY-IET
DOI: 10.1049/iet-rpg.2019.0733

Keywords

fault diagnosis; HVDC power convertors; neural nets; wavelet transforms; HVDC power transmission; power transmission protection; power transmission faults; discrete wavelet transforms; power grids; ANN-based robust DC fault protection algorithm; MMC high-voltage direct current grids; reliable protection; significant technical challenge; modular multilevel converter-based DC grids; existing fault detection methods; protective thresholds; high-resistance faults; artificial neural network-based method; DC bus protection; DC line protection; DC voltages; DC faults; faulted poles; four-terminal MMC-based DC grid; fault identification; intelligent algorithm-based protection scheme

Funding

  1. National Natural Science Foundation of China [U1766211, 51807071]
  2. China Postdoctoral Science Foundation [2017M620320]

Ask authors/readers for more resources

Fast and reliable protection is a significant technical challenge in the modular multilevel converter (MMC)-based DC grids. The existing fault detection methods suffer from the difficulty in setting protective thresholds, incomplete function, insensitivity to high-resistance faults and vulnerable to noise. This study proposes an artificial neural network (ANN)-based method to enable DC bus protection and DC line protection for DC grids. The transient characteristics of DC voltages are analysed during DC faults. On the basis of the analysis, the discrete wavelet transform is used as an extractor of distinctive features at the input of the ANN. Both frequency-domain and time-domain components are selected as input vectors. A large number of offline data considering the impact of noise is employed to train the ANN. The outputs of the ANN are used to trigger the DC line and DC bus protections and select the faulted poles. The proposed method is tested in a four-terminal MMC-based DC grid under PSCAD/EMTDC. The simulation results verify the effectiveness of the proposed method in fault identification and the selection of the faulty pole. The intelligent algorithm-based protection scheme has good performance concerning selectivity, reliability, robustness to noise and fast action.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available