4.6 Article

Microwave-assisted digestion using dilute nitric acid solution and investigation of calibration strategies for determination of As, Cd, Hg and Pb in dietary supplements using ICP-MS

Journal

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume 174, Issue -, Pages 471-478

Publisher

ELSEVIER
DOI: 10.1016/j.jpba.2019.06.018

Keywords

Sample preparation; Diluted nitric acid; Experimental design; Calibration methods; United States Pharmacopeia

Funding

  1. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) [141311/2017-7, 141634/2017-0, 305201/2018-2, 428558/2018-6]
  2. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior - Brasil (CAPES) [001]
  3. Instituto Nacional de Ciencias e Tecnologias Analiticas Avancadas - CNPq [573894/2008-6]
  4. FAPESP [2014/50951-4]
  5. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) [14/50951-4] Funding Source: FAPESP

Ask authors/readers for more resources

This study proposes an analytical procedure for microwave-assisted sample preparation of dietary supplements for athletes using dilute nitric acid solution followed by determination of elemental impurities (As, Cd, Hg and Pb) by inductively coupled plasma mass spectrometry (ICP-MS) according to the United States Pharmacopeia Chapters 2232 and 233. Calibration strategies as internal standardization (IS), multi isotope calibration (MICaI), and one-point standard addition (OP SA) were applied for correction of matrix effects. The optimization of the sample preparation procedure was performed using Doehlert experimental design based on overall desirability results (residual acidity, dissolved organic carbon and recoveries reached for certified reference material of Typical Diet) for each calibration method evaluated. Accuracy was also evaluated by recovery experiments according to the permissible daily exposure specific for each element and samples were spiked with element concentrations of 0.5J and 1.5J in order to check accuracies for As, Cd, Hg and Pb. Recoveries ranged from 82 to 120% using IS, 90 to 125% using MICaI, 88 to 120% using OP SA and the repeatability was demonstrated by a precision lower than 10% RSD. Ten samples of dietary sport supplements were analyzed using the three calibration methods evaluated and the concentrations of As, Cd and Pb determined in eight samples were lower than the limits established by the Chapter 2232. (C) 2019 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available