4.6 Article

The contamination of valsartan and other sartans, Part 2: Untargeted screening reveals contamination with amides additionally to known nitrosamine impurities

Journal

JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume 172, Issue -, Pages 278-284

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jpba.2019.04.035

Keywords

Nitrosamines; Contamination; Valsartan; NDEA; NDMA; Valeramide; LC-MS/HRMS

Ask authors/readers for more resources

The recent incidences of contaminated valsartan drug products gave rise to review the suitability of current impurity profiling workflows implemented at authorities and pharmaceutical companies. The major drawback of targeted impurity profiling, where a considerable amount of prior knowledge about possible contaminants is necessary, is the fact that unexpected impurities are overlooked easily. Here, a generic untargeted approach was applied on sartan containing drug products. The untargeted workflow allowed for the discrimination of different batches, different production sites, and differences after changes in the production process. The presented universal workflow makes use of LC-HRMS/MS and multivariate analysis for the interpretation of the data. Sartan samples contaminated with N-nitrosodimethylamine could be very well discriminated from N-nitrosodimethylamine-free samples using the procedure. Furthermore, untargeted approaches revealed two new impurities in various sartans drug products: valeramide and N,N-dimethylvaleramide. (C) 2019 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available