Performance of the Freestyle Libre flash glucose monitoring (flash GM) system in individuals with type 1 diabetes: A secondary outcome analysis of a randomized crossover trial
Published 2019 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Performance of the Freestyle Libre flash glucose monitoring (flash GM) system in individuals with type 1 diabetes: A secondary outcome analysis of a randomized crossover trial
Authors
Keywords
-
Journal
DIABETES OBESITY & METABOLISM
Volume -, Issue -, Pages -
Publisher
Wiley
Online
2019-07-23
DOI
10.1111/dom.13835
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Impact of physical exercise on sensor performance of the FreeStyle Libre intermittently viewed continuous glucose monitoring system in people with Type 1 diabetes: a randomized crossover trial
- (2019) O. Moser et al. DIABETIC MEDICINE
- Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes
- (2019) Dessi P. Zaharieva et al. Diabetes Technology & Therapeutics
- A New Era in Continuous Glucose Monitoring: Food and Drug Administration Creates a New Category of Factory-Calibrated Nonadjunctive, Interoperable Class II Medical Devices
- (2018) Satish K. Garg et al. Diabetes Technology & Therapeutics
- AN ENDOCRINE CLINIC'S PERSPECTIVE AND EXPERIENCE WITH THE ABBOTT FREESTYLE LIBRE CGM
- (2018) James R. Blum et al. Endocrine Practice
- Interstitial Glucose and Physical Exercise in Type 1 Diabetes: Integrative Physiology, Technology, and the Gap In-Between
- (2018) Othmar Moser et al. Nutrients
- Reduction in insulin degludec dosing for multiple exercise sessions improves time spent in euglycaemia in people with type 1 diabetes: a randomised cross-over trial
- (2018) Othmar Moser et al. DIABETES OBESITY & METABOLISM
- Clinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring
- (2018) Steven V. Edelman et al. DIABETES CARE
- A head-to-head comparison of personal and professional continuous glucose monitoring systems in people with type 1 diabetes: Hypoglycaemia remains the weak spot
- (2018) Othmar Moser et al. DIABETES OBESITY & METABOLISM
- Accuracy of continuous glucose monitoring during differing exercise conditions
- (2016) Lia Bally et al. DIABETES RESEARCH AND CLINICAL PRACTICE
- Comparison of Two Continuous Glucose Monitoring Systems, Dexcom G4 Platinum and Medtronic Paradigm Veo Enlite System, at Rest and During Exercise
- (2016) Nadine Taleb et al. Diabetes Technology & Therapeutics
- Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial
- (2016) Jan Bolinder et al. LANCET
- Accuracy of Continuous Glucose Monitoring (CGM) during Continuous and High-Intensity Interval Exercise in Patients with Type 1 Diabetes Mellitus
- (2016) Othmar Moser et al. Nutrients