4.5 Article

Time-Resolved Freely Dissolved Concentrations of Semivolatile and Hydrophobic Test Chemicals in In Vitro Assays-Measuring High Losses and Crossover by Headspace Solid-Phase Microextraction

Journal

CHEMICAL RESEARCH IN TOXICOLOGY
Volume 32, Issue 9, Pages 1780-1790

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/acs.chemrestox.9b00133

Keywords

-

Funding

  1. CEFIC Long-Range Research Initiative (LRI), Project ECO36
  2. National Centre for the Replacement, Refinement and Reduction of Animals in Research (NC3Rs) (Crack-it Challenge 27: DoCE)

Ask authors/readers for more resources

In vitro assays are normally conducted in plastic multiwell plates open to exchange with the ambient air. The concentration of test substances freely available to cells is often not known, can change over time, and is difficult to measure in the small volumes in microplates. However, even a well-characterized toxicological response is of limited value if it cannot be linked to a well-defined exposure level. The aim of this study was to develop and apply an approach for determining time-resolved freely dissolved concentrations of semivolatile and hydrophobic organic chemicals (SVHOCs) in in vitro assays: (1) free fractions were measured by a new medium dilution method and (2) time-resolved loss curves were obtained by measurements of total concentrations in 96-well plates during incubations at 37 degrees C. Headspace solid-phase microextraction was used as an analytical technique for 24 model chemicals spanning 6 chemical groups and 4-5 orders of magnitude in K-ow and K-aw. Free fractions were >30% for chemicals with log K-ow < 3.5 and then decreased with increasing log Kow. Medium concentrations declined significantly (>50%) within 24 h of incubation for all 20 chemicals having log K-ow > 4 or log K-aw > -3.5 in serum-free medium. Losses of chemicals were lower for medium containing 10% fetal bovine serum, most significantly for chemicals with log K-ow > 4. High crossover to neighboring wells also was observed below log K-ow of 4 and log K-aw of -3.5. Sealing the well plates had limited effect on the losses but clearly reduced crossover. The high losses and crossover of most tested chemicals question the suitability of multiwell plates for in vitro testing of SVHOCs and call for (1) test systems that minimize losses, (2) methods to control in vitro exposure, (3) analytical confirmation of exposure, and (4) exposure control and confirmation being included in good in vitro reporting standards.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available