4.6 Article

Adaptation of controlled attenuation parameter (CAP) measurement depth in morbidly obese patients addressed for bariatric surgery

Journal

PLOS ONE
Volume 14, Issue 5, Pages -

Publisher

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0217093

Keywords

-

Ask authors/readers for more resources

Background and aim The controlled attenuation parameter (CAP) using FibroScan (Echosens, Paris, France) M or XL probe has been developed for liver steatosis assessment. However, CAP performs poorly in patients with high body mass index. The aim of our study was to assess whether CAP is overestimated using the standard XL probe in patients with morbid obesity, and in the case of an overestimation, to reprocess the data at a greater depth to obtain the appropriate CAP (CAPa). Patients and methods We conducted an observational prospective cohort study on a total of 249 severely obese patients admitted to our institution to undergo sleeve gastrectomy. Patients had a liver biopsy performed during the surgery and a CAP measurement during the 15 days preceding biopsy. Patient files were reprocessed retrospectively by an algorithm, blinded to the patients' clinical data. The algorithm automatically assessed the probe-to-capsula distance (PCD) by analysing the echogenicity of ultrasound signals on the time-motion mode. In the case of a distance >35 mm, the algorithm automatically selected a deeper measurement for CAP (CAPa). When PCD was less than 35 mm, the measured CAP was considered as appropriated (CAPa) and no further reprocessing was performed. Results CAP recording was not performed at a sufficient depth in 130 patients. In these patients, the CAPa obtained at the adapted depth was significantly lower than CAP (298 +/- 3.9 versus 340 +/- 4.2 dB/m; p<0.0001) measured at the standard depth (35 to 75 mm). Multiple linear regression analysis revealed that both body mass index and hepatic steatosis were independently correlated with CAP values. After reprocessing the CAP in patients with PCD > 35 mm, steatosis stage was the only parameter independently correlated with CAP values. For the diagnosis of steatosis (S >= 1), moderate to severe steatosis (S >= 2) and severe steatosis (S = 3), the AUROC curves of CAPa (measured CAP in patients with PCD<35 mm and reprocessed CAP in those with PCD>35 mm) were 0.86, 0.83 and 0.79, respectively. The Obuchowski measure for the diagnosis of steatosis was 0.90 +/- 0.013. Conclusion CAP was overestimated in a half of morbidly obese patients using an XL probe, but CAP can be performed correctly in these patients after adapting the measurement depth.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available