4.6 Article

Magnetized Carbon Nanotube Based Lateral Flow Immunoassay for Visual Detection of Complement Factor B

Journal

MOLECULES
Volume 24, Issue 15, Pages -

Publisher

MDPI
DOI: 10.3390/molecules24152759

Keywords

Magnetized carbon nanotube; lateral flow immunoassay; complement factor B; blood

Funding

  1. National Institute of Health, Centers of Biomedical Research Excellence (NIH, COBRE) [P20 GM109024]
  2. National Natural Science Foundation of China [31700735]
  3. National Natural Science Foundation of Anhui Province [1908085MB54, 1808085QH264]
  4. Beijing Natural Science Foundation [2122038]
  5. Wanjiang scholar Award of Anhui Province
  6. Basic research business fund of central universities [FRF-TP-18-020A1]
  7. China Postdoctoral Science Foundation [2018M631332]

Ask authors/readers for more resources

The authors describe a magnetized carbon nanotube (MCNT) based lateral flow immunoassay (LFI) for visual detection of complement factor B (CFB) in blood. MCNT was prepared by decorating magnetic Fe3O4 nanoparticles on multi-walled CNT surface and used as a colored tag for LFI. Monoclonal antibody (mAb, Ab(1)) of CFB was covalently immobilized on the MCNT surface via diimide-activated conjugation between the carboxyl groups on the MCNT surface and amino groups of antibodies. Polyclonal antibody of CFB (Ab(2)) and the secondary antibody were used to prepare the lateral flow test strips. The assay involved: (1) the capture of CFB in blood with the mAb-functionalized MCNT; (2) magnetic separation of the formed CFB-mAb-MCNT and excess of mAb-MCNT from the blood with an external magnet; (3) lateral flow test to capture the CFB-mAb-MCNT complex on the test zone and the excess of mAb-MCNT on the control zone; (4) Recording the intensities of the produced the characteristic brown bands with a portable strip reader and quantitating the concentration of CFB. The proof-of-concept was demonstrated by testing CFB in the buffer, and the detection limit was 5 ng mL(-1) under the optimized analytical parameters. CFB in 1 mu L of human blood was detected successfully in 30 min with this LFI and the results had a high correlation with commercial ELISA kit. Thence, the MCNT-based LFI offers a rapid and low-cost tool for detecting CFB in human blood directly.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available