Comparison of ultra-low dose chest CT scanning protocols for the detection of pulmonary nodules: a phantom study
Published 2019 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Comparison of ultra-low dose chest CT scanning protocols for the detection of pulmonary nodules: a phantom study
Authors
Keywords
-
Journal
TUMORI
Volume -, Issue -, Pages 030089161984727
Publisher
SAGE Publications
Online
2019-05-01
DOI
10.1177/0300891619847271
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Comparison of computer-aided detection (CADe) capability for pulmonary nodules among standard-, reduced- and ultra-low-dose CTs with and without hybrid type iterative reconstruction technique
- (2018) Yoshiharu Ohno et al. EUROPEAN JOURNAL OF RADIOLOGY
- Long-term Active Surveillance of Screening Detected Subsolid Nodules is a Safe Strategy to Reduce Overtreatment
- (2018) Mario Silva et al. Journal of Thoracic Oncology
- Detection of artificial pulmonary lung nodules in ultralow-dose CT using an ex vivo lung phantom
- (2018) Caroline Alexandra Burgard et al. PLoS One
- Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose – a prospective intra-individual comparative study
- (2017) Michael Messerli et al. EUROPEAN RADIOLOGY
- Lung cancer screening with ultra-low dose CT using full iterative reconstruction
- (2017) Masayo Fujita et al. JAPANESE JOURNAL OF RADIOLOGY
- Lung-RADS: Pushing the Limits
- (2017) Maria D. Martin et al. RADIOGRAPHICS
- Lung cancer screening with ultra-low dose CT using full iterative reconstruction
- (2017) Masayo Fujita et al. Japanese Journal of Radiology
- Exposure to low dose computed tomography for lung cancer screening and risk of cancer: secondary analysis of trial data and risk-benefit analysis
- (2017) Cristiano Rampinelli et al. BMJ-British Medical Journal
- Exposure to low dose computed tomography for lung cancer screening and risk of cancer: secondary analysis of trial data and risk-benefit analysis
- (2017) Cristiano Rampinelli et al. BMJ-British Medical Journal
- Screening for lung cancer using sub-millisievert chest CT with iterative reconstruction algorithm: image quality and nodule detectability
- (2017) Miao Zhang et al. BRITISH JOURNAL OF RADIOLOGY
- Lung Cancer Screening
- (2017) Douglas E. Wood et al. Journal of the National Comprehensive Cancer Network
- Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT
- (2016) K. Martini et al. EUROPEAN JOURNAL OF RADIOLOGY
- Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13 mSv
- (2016) Michael Messerli et al. EUROPEAN JOURNAL OF RADIOLOGY
- Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT
- (2016) Xin Sui et al. EUROPEAN JOURNAL OF RADIOLOGY
- Effect of radiation dose reduction and iterative reconstruction on computer-aided detection of pulmonary nodules: Intra-individual comparison
- (2016) Annemarie M. Den Harder et al. EUROPEAN JOURNAL OF RADIOLOGY
- Natural History of Pulmonary Subsolid Nodules: A Prospective Multicenter Study
- (2016) Ryutaro Kakinuma et al. Journal of Thoracic Oncology
- Ultra-Low-Dose CT of the Thorax Using Iterative Reconstruction: Evaluation of Image Quality and Radiation Dose Reduction
- (2015) Yookyung Kim et al. AMERICAN JOURNAL OF ROENTGENOLOGY
- Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study
- (2015) Katharina Martini et al. BRITISH JOURNAL OF RADIOLOGY
- ESR/ERS white paper on lung cancer screening
- (2015) Hans-Ulrich Kauczor et al. EUROPEAN RESPIRATORY JOURNAL
- State of the Art: Iterative CT Reconstruction Techniques
- (2015) Lucas L. Geyer et al. RADIOLOGY
- Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
- (2014) So Won Lee et al. EUROPEAN RADIOLOGY
- Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility
- (2014) Franziska M. Braun et al. EUROPEAN RADIOLOGY
- Ultralow-Dose Chest Computed Tomography for Pulmonary Nodule Detection
- (2014) Sonja Gordic et al. INVESTIGATIVE RADIOLOGY
- Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecified analysis of data from the NELSON trial of low-dose CT screening
- (2014) Nanda Horeweg et al. LANCET ONCOLOGY
- Update in the Evaluation of the Solitary Pulmonary Nodule
- (2014) Mylene T. Truong et al. RADIOGRAPHICS
- Computer-Aided Segmentation and Volumetry of Artificial Ground-Glass Nodules at Chest CT
- (2013) Ernst Th. Scholten et al. AMERICAN JOURNAL OF ROENTGENOLOGY
- Definition of a Positive Test Result in Computed Tomography Screening for Lung Cancer
- (2013) Claudia I. Henschke ANNALS OF INTERNAL MEDICINE
- Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations
- (2012) Angeliki Neroladaki et al. EUROPEAN RADIOLOGY
- Benefits and Harms of CT Screening for Lung Cancer
- (2012) Peter B. Bach et al. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION
- Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
- (2011) NEW ENGLAND JOURNAL OF MEDICINE
Find Funding. Review Successful Grants.
Explore over 25,000 new funding opportunities and over 6,000,000 successful grants.
ExploreAdd your recorded webinar
Do you already have a recorded webinar? Grow your audience and get more views by easily listing your recording on Peeref.
Upload Now