4.6 Article

Resurfacing in a Posterior-Stabilized Total Knee Arthroplasty Reduces Patellar Crepitus Complication: A Randomized, Controlled Trial

Journal

JOURNAL OF ARTHROPLASTY
Volume 34, Issue 9, Pages 1969-1974

Publisher

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2019.04.050

Keywords

patellar crepitus; total knee arthroplasty; patellar resurfacing; patellar non-resurfacing; posterior-stabilized

Categories

Funding

  1. Navamindradhiraj University Research Fund, Thailand [CEU/C 032/2560]

Ask authors/readers for more resources

Background: Patellar crepitus (PC) is a common complication after total knee arthroplasty (TKA) using a posterior-stabilized (PS) prosthesis. While numerous factors have been associated with PC development after PS-TKA, patellar resurfacing (PR) which directly impacts the patellofemoral joint kinematics has been underinvestigated. A prospective, randomized, controlled trial was conducted to (1) compare the PC incidence in PR and non-PR PS-TKA, (2) determine the time of PC presentation in PS-TKA, (3) identify radiographic parameters associated with PC, and (4) compare clinical outcomes of patients with and without PR. Methods: A total of 84 patients who underwent unilateral TKA using the Legion PS Total Knee System were randomized into PR group or non-PR group. PC incidence, time of PC presentation, radiographic parameters associated with PC development, and clinical outcomes were evaluated at 3 months, 6 months, 9 months, and 1 year postoperatively. Results: PC occurred significantly more in the non-PR group (23.1% vs 7.3%, P = .048). Time of PC presentation in both groups was not different. Anterior knee pain was found in 16.7% of crepitus patients, and none required any surgical procedure. The non-PR knees had significant decreases in patellar shift index, patellar displacement, Insall-Salvati ratio, and patellar component height and increase in change in posterior femoral offset. Oxford and patellar scores were significantly better in the PR group at 9 months and 1 year. Conclusion: Given higher PC incidence and several worse clinical outcomes in the non-PR, we recommend resurfacing during PS-TKA with this knee system to avoid PC development. (C) 2019 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available