Journal
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
Volume 99, Issue -, Pages 80-93Publisher
ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2018.12.008
Keywords
Ejector refrigeration system; Solar energy; Exergy; Exergoeconomic analysis
Categories
Ask authors/readers for more resources
In this article, the economic performance of the solar-driven steam ejector refrigeration system is addressed due to the rising beneficial adoption of this system with regard to using low-grade heat sources. For this purpose, a detailed exergoeconomic analysis on four proposed configurations of this system integrated with either or both of a precooler and a preheater is performed. At a refrigeration load of 5 kW, the results of this analysis show that it is more advantageous for all configurations to have evaporators work at 278 K with condensers remain at 311 K, whilst the generators are kept working at 362 K. The characteristics of each configuration are comprehensively discussed and compared. Based on the assessment of economic parameters, the fourth configuration provides the highest exergetic efficiency and the lowest total investment cost (0.1891 $/h) compared to the other configurations. The current work furnishes essential information that paves the way for future exergoeconomic studies in this field. (C) 2018 Elsevier Ltd and IIR. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available