4.4 Article

Guideline for minimizing radiation exposure during acquisition of coronary artery calcium scans with the use of multidetector computed tomography

Journal

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcct.2011.01.003

Keywords

Coronary artery calcium; Radiation exposure; Radiation dose; Guideline; Multidetector CT

Funding

  1. Lantheus
  2. GE/Amersham
  3. Siemens
  4. Astellas Healthcare
  5. Astellas Pharma
  6. Pfizer
  7. IMC
  8. GE Healthcare
  9. Siemens Healthcare
  10. Toshiba America Medical Systems
  11. Vital Images

Ask authors/readers for more resources

Coronary artery calcium (CAC) scanning is an important tool for risk stratification in intermediate-risk, asymptomatic subjects without previous coronary disease. However, the clinical benefit of improved risk prediction needs to be balanced against the risk of the use of ionizing radiation. Although there is increasing emphasis on the need to obtain CAC scans at low-radiation exposure to the patient, very few practical documents exist to aid laboratories and health care professionals on how to obtain such low-radiation scans. The Tomographic Imaging Council of the Society for Atherosclerosis Imaging and Prevention, in collaboration with the Prevention Council and the Society of Cardiovascular Computed Tomography, created a task force and writing group to generate a practical document to address parameters that can be influenced by careful attention to image acquisition. Patient selection for CAC scanning should be based on national guidelines. It is recommended that laboratories performing CAC examinations monitor radiation exposure (dose-length-product [ DLP]) and effective radiation dose (E) in all patients. DLP should be <200 mGy x cm; E should average 1.0-1.5 mSv and should be <3.0 mSv. On most scanner platforms, CAC imaging should be performed in an axial mode with prospective electrocardiographic triggering, using tube voltage of 120 kVp. Tube current should be carefully selected on the basis of patient size, potentially using chest lateral width measured on the topogram. Scan length should be limited for the coverage of the heart only. When patients and imaging parameters are selected appropriately, CAC scanning can be performed with low levels of radiation exposure. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available