Investigation of a Polyaniline-Coated Copper Hexacyanoferrate Modified Glassy Carbon Electrode as a Sulfite Sensor
Published 2014 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Investigation of a Polyaniline-Coated Copper Hexacyanoferrate Modified Glassy Carbon Electrode as a Sulfite Sensor
Authors
Keywords
Polyaniline, Copper hexacyanoferrate, Glassy carbon, Electrocatalysis, Sulfite
Journal
Electrocatalysis
Volume 5, Issue 4, Pages 344-353
Publisher
Springer Nature
Online
2014-04-07
DOI
10.1007/s12678-014-0199-9
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Simultaneous determination of ascorbic acid, epinephrine and uric acid at over-oxidized poly(p-aminophenol) film modified electrode
- (2013) Çağrı Ceylan Koçak et al. JOURNAL OF ELECTROANALYTICAL CHEMISTRY
- Studies of conducting polyaniline (PANI) wrapped-multiwalled carbon nanotubes (MWCNTs) nanocomposite and its application for optical pH sensing
- (2013) Milind V. Kulkarni et al. SENSORS AND ACTUATORS B-CHEMICAL
- Recent advances in polyaniline composites with metals, metalloids and nonmetals
- (2013) Gordana Ćirić-Marjanović SYNTHETIC METALS
- Surviving in the presence of sulphur dioxide: strategies developed by wine yeasts
- (2012) Benoit Divol et al. APPLIED MICROBIOLOGY AND BIOTECHNOLOGY
- Voltammetric simultaneous determination of glucose, ascorbic acid and dopamine on glassy carbon electrode modified byNiNPs@poly 1,5-diaminonaphthalene
- (2012) A.A. Hathoot et al. ELECTROCHIMICA ACTA
- Electrodeposited polyaniline on Pd-loaded TiO2 nanotubes as active material for electrochemical supercapacitor
- (2012) Fereydoon Gobal et al. JOURNAL OF ELECTROANALYTICAL CHEMISTRY
- Chemiluminescence determination of sulphite using a cyclometalated iridium complex as chemiluminescence reagent
- (2012) Fanghui Wu et al. LUMINESCENCE
- Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode
- (2011) Rachna Rawal et al. ANALYTICAL AND BIOANALYTICAL CHEMISTRY
- Organic–inorganic composites consisted of poly(3,4-ethylenedioxythiophene) and Prussian Blue analogues
- (2011) Anna Lisowska-Oleksiak et al. ELECTROCHIMICA ACTA
- Au nanocages for highly sensitive and selective detection of H2O2
- (2011) Yue Zhang et al. JOURNAL OF ELECTROANALYTICAL CHEMISTRY
- Glassy carbon electrode modified by conductive polyaniline coating for determination of trace lead and cadmium ions in acetate buffer solution
- (2011) Zhaomeng Wang et al. THIN SOLID FILMS
- Simultaneous determination of catecholamines, uric acid and ascorbic acid at physiological levels using poly(N-methylpyrrole)/Pd-nanoclusters sensor
- (2010) Nada F. Atta et al. ANALYTICAL BIOCHEMISTRY
- A fast and sensitive HPLC method for sulfite analysis in food based on a plant sulfite oxidase biosensor
- (2010) S. Theisen et al. BIOSENSORS & BIOELECTRONICS
- Recent advances in polyaniline based biosensors
- (2010) Chetna Dhand et al. BIOSENSORS & BIOELECTRONICS
- Amperometric NADH Biosensor Based on Magnetic Chitosan Microspheres/Poly(thionine) Modified Glassy Carbon Electrode
- (2010) Ya Liu et al. ELECTROANALYSIS
- An amperometric sensor based on Prussian blue and poly(o-phenylenediamine) modified glassy carbon electrode for the determination of hydrogen peroxide in beverages
- (2010) Jianfeng Ping et al. FOOD CHEMISTRY
- Electrochemical preparation of copper hexacyanoferrate nanoparticles under the synergic action of EDTA and HAuCl4
- (2010) Hao Yu et al. JOURNAL OF ELECTROANALYTICAL CHEMISTRY
- Amperometric glucose biosensor by means of electrostatic layer-by-layer adsorption onto polyaniline-coated polyester films
- (2010) Young Jae Shin et al. JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY
- Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode
- (2010) Lori Shayne T. Alamo et al. TALANTA
- Electrochemical sensing based on carbon nanotubes
- (2010) Paloma Yáñez-Sedeño et al. TRAC-TRENDS IN ANALYTICAL CHEMISTRY
- Sulfite biosensor based on osmium redox polymer wired sulfite oxidase
- (2009) Roberto Spricigo et al. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS
- Electrochemical sensor for sulfite determination based on a nanostructured copper-salen film modified electrode
- (2009) Tony R.L. Dadamos et al. ELECTROCHIMICA ACTA
- Amperometric glucose biosensor with high sensitivity based on self-assembled Prussian Blue modified electrode
- (2009) Yu Liu et al. ELECTROCHIMICA ACTA
- Composite electrodes consisting Pt nano-particles and poly (aminophenols) film on pre-treated aluminum substrate as electrocatalysts for methanol oxidation
- (2009) Biuck Habibi et al. JOURNAL OF SOLID STATE ELECTROCHEMISTRY
- Conducting polymer coated carbon surfaces and biosensor applications
- (2009) Murat Ates et al. PROGRESS IN ORGANIC COATINGS
- Conducting polymers in chemical sensors and arrays
- (2008) Ulrich Lange et al. ANALYTICA CHIMICA ACTA
- Cholesterol biosensor based on electrochemically prepared polyaniline conducting polymer film in presence of a nonionic surfactant
- (2008) Raju Khan et al. JOURNAL OF POLYMER RESEARCH
- Amperometric sulfite sensor based on multiwalled carbon nanotubes/ferrocene-branched chitosan composites
- (2008) Hong Zhou et al. TALANTA
Publish scientific posters with Peeref
Peeref publishes scientific posters from all research disciplines. Our Diamond Open Access policy means free access to content and no publication fees for authors.
Learn MoreBecome a Peeref-certified reviewer
The Peeref Institute provides free reviewer training that teaches the core competencies of the academic peer review process.
Get Started