4.5 Review

Facial Nerve Monitoring During Cerebellopontine Angle and Skull Base Tumor Surgery: A Systematic Review from Description to Current Success on Function Prediction

Journal

WORLD NEUROSURGERY
Volume 80, Issue 6, Pages E271-E300

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.wneu.2011.09.026

Keywords

Cerebellopontine angle surgery; Direct electrical stimulation; Electromyography; Facial motor evoked potential; Facial nerve; Intraoperative monitoring; Skull base surgery

Ask authors/readers for more resources

BACKGROUND: Intraoperative neuromonitoring has been established as one of the methods by which modern neurosurgery can improve surgical results while reducing morbidity. Despite routine use of intraoperative facial nerve (FN) monitoring, FN injury still is a complication of major concern due to severe negative impact on patient's quality of life. METHODS: Through searches of PubMed, we provided a systematic review of the current literature up to February, 2011, emphasizing all respects of FN monitoring for cerebellopontine angle and skull base tumor surgery from description to current success on function prediction of standard and emerging monitoring techniques. RESULTS: Currently, standard monitoring techniques comprise direct electrical stimulation (DES), free-running electromyography (EMG), and facial motor evoked potential (FMEP). We included 62 studies on function prediction by investigating DES (43 studies), free-running EMG (13 studies), and FMEP (6 studies) criteria. DES mostly evaluated postoperative function by using absolute amplitude, stimulation threshold, and proximal-to-distal amplitude ratio, whereas free-running EMG used the train-time criterion. The prognostic significance of FMEP was assessed with the final-to-baseline amplitude ratio, as well as the event-to-baseline amplitude ratio and waveform complexity. CONCLUSIONS: Although there is a general agreement on the satisfactory functional prediction of different electrophysiological criteria, the lack of standardization in electrode montage and stimulation parameters precludes a definite conclusion regarding the best method. Moreover, studies emphasizing comparison between criteria or even multimodal monitoring and its impact on FN anatomical and functional preservation are still lacking in the literature.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available