In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor
Published 2013 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor
Authors
Keywords
-
Journal
Biomedical Optics Express
Volume 5, Issue 1, Pages 275
Publisher
The Optical Society
Online
2013-12-17
DOI
10.1364/boe.5.000275
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
- (2013) Jonas Kottmann et al. SENSORS
- In vivo measurement of mid-infrared light scattering from human skin
- (2013) Anna P. M. Michel et al. Biomedical Optics Express
- In vitro measurements of physiological glucose concentrations in biological fluids using mid-infrared light
- (2013) Sabbir Liakat et al. Biomedical Optics Express
- Discussion on the validity of NIR spectral data in non-invasive blood glucose sensing
- (2013) Wanjie Zhang et al. Biomedical Optics Express
- Direct determination of glucose, lactate and triglycerides in blood serum by a tunable quantum cascade laser-based mid-IR sensor
- (2012) M. Brandstetter et al. APPLIED PHYSICS B-LASERS AND OPTICS
- Noninvasive glucose detection in human skin using wavelength modulated differential laser photothermal radiometry
- (2012) Xinxin Guo et al. Biomedical Optics Express
- Continuous glucose monitoring by means of mid-infrared transmission laser spectroscopy in vitro
- (2011) Christian Vrančić et al. ANALYST
- Tunable mid-infrared lasers in physical chemosensors towards the detection of physiologically relevant parameters in biofluids
- (2011) Markus Brandstetter et al. SENSORS AND ACTUATORS B-CHEMICAL
- Infrared spectroscopic analysis of human interstitial fluid in vitro and in vivo using FT-IR spectroscopy and pulsed quantum cascade lasers (QCL): Establishing a new approach to non invasive glucose measurement
- (2011) Miguel Pleitez et al. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY
- External cavity quantum cascade laser tunable from 7.6 to 11.4 μm
- (2009) Andreas Hugi et al. APPLIED PHYSICS LETTERS
- New Features and Performance of a Next-Generation SEVEN-Day Continuous Glucose Monitoring System with Short Lag Time
- (2009) Timothy Bailey et al. Diabetes Technology & Therapeutics
- Evaluating the Accuracy, Reliability, and Clinical Applicability of Continuous Glucose Monitoring (CGM): Is CGM Ready for Real Time?
- (2009) Roger S. Mazze et al. Diabetes Technology & Therapeutics
- Fiber-Optic Evanescent Wave Spectroscopy in the Middle Infrared
- (2008) Y. Raichlin et al. APPLIED SPECTROSCOPY
- Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish
- (2008) Hideaki Endo et al. BIOSENSORS & BIOELECTRONICS
- Two-wavelength carbon dioxide laser application for in-vitro blood glucose measurements
- (2008) Martina Meinke et al. JOURNAL OF BIOMEDICAL OPTICS
Find Funding. Review Successful Grants.
Explore over 25,000 new funding opportunities and over 6,000,000 successful grants.
ExplorePublish scientific posters with Peeref
Peeref publishes scientific posters from all research disciplines. Our Diamond Open Access policy means free access to content and no publication fees for authors.
Learn More