3.9 Article

Results and complications in the treatment of periprosthetic femur fractures with a locked plate system

Journal

UNFALLCHIRURG
Volume 113, Issue 3, Pages 195-+

Publisher

SPRINGER
DOI: 10.1007/s00113-009-1665-3

Keywords

Periprosthetic femur fractures; Total knee arthroplasty; Total hip arthroplasty; Locked plating

Ask authors/readers for more resources

Background. Locked plate devices offer advantages in the treatment of periprosthetic femur fractures associated with fixed total hip or total knee arthroplasty. The purpose of this study was to evaluate the early results and complications with a locked plate system (NCB-DF(R)). Patients and methods. A total of 31 patients (mean age 76 years, 7 males, 24 females) with a femur fracture above a fixed total knee arthroplasty (TKA, n=12) or a total hip arthroplasty (THA, n=19) were treated with a locked plate. Results. There were 11 complications necessitating revision: 6 implant failures, 2 in patients with a THA and 4 in patients with a TKA, 4 hematomas and 1 infection and 2 patients died. After 6 months all fractures had healed securely but a secondary correction was necessary in one patient. Conclusion. Fixation of periprosthetic femur fractures with a locked plate system provided satisfactory results in patients with a THA, however, the relatively high implant failure rate in fractures above a stable TKA is a cause for concern.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.9
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available