4.7 Article Proceedings Paper

Cavitation occurrence around ultrasonic dental scalers

Journal

ULTRASONICS SONOCHEMISTRY
Volume 16, Issue 5, Pages 692-697

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.ultsonch.2008.11.002

Keywords

Sonochemiluminescence; Scanning laser vibrometry; Dental instruments; Cavitation

Funding

  1. EPSRC [EP/C536894/1] Funding Source: UKRI
  2. Engineering and Physical Sciences Research Council [EP/C536894/1, EP/C536908/1] Funding Source: researchfish

Ask authors/readers for more resources

Ultrasonic scalers are used in dentistry to remove calculus and other contaminants from teeth. One mechanism which may assist in the cleaning is cavitation generated in cooling water around the scaler. The vibratory motion of three designs of scaler tip in a water bath has been characterised by laser vibrometry, and compared with the spatial distribution of cavitation around the scaler tips observed using sonochemiluminescence from a luminol solution. The type of cavitation was confirmed by acoustic emission analysed by a 'Cavimeter' supplied by NPL. A node/antinode vibration pattern was observed, with the maximum displacement of each type of tip occurring at the free end. High levels of cavitation activity occurred in areas surrounding the vibration antinodes, although minimal levels were observed at the free end of the tip. There was also good correlation between vibration amplitude and sonochemiluminescence at other points along the scaler tip. 'Cavimeter' analysis correlated well with luminol observations, suggesting the presence of primarily transient cavitation. (C) 2008 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available