4.7 Article Proceedings Paper

Sensitive fluorimetric flow injection analysis for fluoride ion with a novel reagent, 2′,7′-dichlorofluorescein di-tert-butyldimethylsilyl ether

Journal

TALANTA
Volume 84, Issue 5, Pages 1361-1365

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2011.03.081

Keywords

Fluoride ion; 2 ',7 '-dichlorofluorescein-di-tert-butyldimethylsilyl ether; Fluorimetric flow injection analysis; Water

Funding

  1. Grants-in-Aid for Scientific Research [22550075] Funding Source: KAKEN

Ask authors/readers for more resources

A novel reagent, 2',7'-dichlorofluorescein di-tert-butyldimethylsilyl ether (FCl2TBS), was synthesized for fluoride ion and used for a sensitive fluorimetric flow injection analysis by detecting the recovery of fluorescence due to cleavage of Si-O bond. Four kinds of fluorescein di-tert-butyldimethylsilyl ether (FTBS) analogues were synthesized and FCl2TBS was the best. By introducing chlorine to FIBS, stability of the reagent, reactivity and the baseline signals were improved. The FIA system was three lines. The sample solution (aqua medium) was injected in the carrier solution (water) and merged with the reagent solution (2.0 x 10(-5) M FCl2TBS acetone solution), then mixed with phosphate buffer solution (pH 7.5). The fluorescence intensities were measured at lambda(ex) 503 nm and lambda(em) 527 nm. The calibration graph had linear relationship between (1.0-50.0) x 10(-6) M and the determinable limit was 1.0 x 10(-6) M. The relative standard deviation of 12 measurements with 1.0 x 10(-6) M F- solution was 1.0% and the sample throughput was 13 h(-1). The developed method was successfully applied to river and tap water samples. (C) 2011 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available