Kinematics of Cervical Total Disc Replacement Adjacent to a Two-Level, Straight Versus Lordotic Fusion

Journal

SPINE
Volume 36, Issue 17, Pages 1359-1366

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BRS.0b013e318222d4ad

Keywords

cervical spine; fusion; total disc replacement; spine biomechanics

Funding

  1. Corporate/Industry, Federal, and Institutional funds
  2. Department of Veterans Affairs, Washington, DC
  3. Synthes Spine, Paoli, PA

Ask authors/readers for more resources

Study Design. In vitro biomechanical study. Objective. To characterize cervical total disc replacement (TDR) kinematics above two-level fusion, and to determine the effect of fusion alignment on TDR response. Summary of Background Data. Cervical TDR may be a promising alternative for a symptomatic adjacent level after prior multilevel cervical fusion. However, little is known about the TDR kinematics in this setting. Methods. Eight human cadaveric cervical spines (C2-T1, age: 59 +/- 8.6 years) were tested intact, after simulated two-level fusion (C4-C6) in lordotic alignment and then in straight alignment, and after C3-C4 TDR above the C4-C6 fusion in lordotic and straight alignments. Fusion was simulated using an external fixator apparatus, allowing easy adjustment of C4-C6 fusion alignment, and restoration to intact state upon disassembly. Specimens were tested in flexion-extension using hybrid testing protocols. Results. The external fixator device significantly reduced range of motion (ROM) at C4-C6 to 2.0 +/- 0.6 degrees, a reduction of 89 +/- 3.0% (P < 0.05). Removal of the fusion construct restored the motion response of the spinal segments to their intact state. The C3-C4 TDR resulted in less motion as compared to the intact segment when the disc prosthesis was implanted either as a stand-alone procedure or above a two-level fusion. The decrease in motion of C3-C4 TDR was significant for both lordotic and straight fusions across C4-C6 (P < 0.05). Flexion and extension moments needed to bring the cervical spine to similar C2 motion endpoints significantly increased for the TDR above a two-level fusion compared to TDR alone (P < 0.05). Lordotic fusion required significantly greater flexion moment, whereas straight fusion required significantly greater extension moment (P < 0.05). Conclusion. TDR placed adjacent to a two-level fusion is subjected to a more challenging biomechanical environment as compared to a stand-alone TDR. An artificial disc used in such a clinical scenario should be able to accommodate the increased moment loads without causing impingement of its endplates or undue wear during the expected life of the prosthesis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available