4.6 Article

Multiple emission line analysis for improved isotopic determination of uranium - a computer simulation study

Journal

SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY
Volume 89, Issue -, Pages 40-49

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.sab.2013.09.001

Keywords

Laser-induced breakdown spectroscopy; Isotopic analysis; Uranium; Partial least square; Isotopic splitting

Categories

Funding

  1. Defense Nuclear Nonproliferation Research and Development Office of the U.S. Department of Energy at the Lawrence Berkeley National Laboratory [DE-AC02-05CH11231]

Ask authors/readers for more resources

Forty-three atomic emission lines for U-235 and U-238 were compiled for computer simulation of isotopic analysis using laser induced breakdown spectroscopy (LIBS). The spectral line profile was assumed to be Lorentzian in shape and the magnitude of three common types of noises (detector-read, photon-shot and flicker) were experimentally determined and incorporated into the simulation. Precision and root mean square error of prediction (RMSEP) for isotopic analysis of a single U line were simulated, and it was found that analytical performance (precision) primarily depended on the signal-to-background ratio (SBR) and net intensity of the emission line, rather than on the magnitude of isotopic splitting (IS), when partial least squares (PIS) was used for calibration. This is because PLS multivariate calibration can be performed correctly even when the spectra are only partially resolved, which in turn relaxes the requirement on having IS larger than the spectral resolution. The analytical performance was found to improve with multiple-line analysis. Depending on the criteria (e.g., SBR, net intensity, magnitude of IS, or best single-line performance) used in sorting the spectral lines into the multiline pool, improvement factors ranging from 2x to 9x were obtained. The absolute uncertainty of isotopic analysis is practically constant and independent of isotopic abundance, which makes experimental estimation of the detection limit in isotopic analysis straightforward because one can experimentally measure this uncertainty with one arbitrary and conveniently chosen isotopic standard and then estimate the detection limit through simple extrapolation. Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available