4.6 Article

Dynamic performance of a facade-based solar loop heat pipe water heating system

Journal

SOLAR ENERGY
Volume 86, Issue 5, Pages 1632-1647

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.solener.2012.02.031

Keywords

Loop heat pipe; Solar radiation; Heat exchanger; Hot water; Efficiency; COP

Categories

Ask authors/readers for more resources

This paper reported a dedicated study of a novel facade-based solar loop heat pipe (LHP) water heating system using both theoretical and experimental methods. This system employs a modular panel incorporating a unique loop heat pipe that is able to serve as part of the building facade or a decoration layer of the facade, thus creating a facade integrated, low cost, highly efficient and aesthetically appealing solar water heating structure. Taking into account heat balances occurring in different parts of the system, e.g., solar absorber, heat pipes loop, heat exchanger and storage tank, a dedicated computer model was developed to investigate the dynamic performance of the system. An experimental rig was also established to evaluate the performance of such a prototype system through measurement of various operational parameters, e.g., solar radiation, temperatures and flow rates of the heat pipe fluid and water. Through comparison between the testing and modelling results, the model has been approved to be able to give a reasonable accuracy for predicting the performance of the LHP system. Two types of glass covers, i.e., double glazed/evacuated tubes and single-glazing plate, were applied to the prototype. It was found that for both covers, the heat pipe fluid temperature rose dramatically at the start-up operation and afterwards remained a slow but steady growth; while the water temperature remained a steadily growing trend throughout the operational day. The temperature rise of the circulated water at 1.61/min of flow rate was around 13.5 degrees C in the double-glazed/evacuated tubes based system and 10 degrees C in the single-glazing based system; correspondingly, their average solar conversion efficiencies were 48.8% and 36%, and the COPs were 14 and 10.5 respectively. In overall, the double-glazed/evacuated tubes based system presented a better performance than the single glazing based one. (C) 2012 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available