4.5 Article

Dielectric microwave resonators in TE011 cavities for electron paramagnetic resonance spectroscopy

Journal

REVIEW OF SCIENTIFIC INSTRUMENTS
Volume 79, Issue 9, Pages -

Publisher

AIP Publishing
DOI: 10.1063/1.2976033

Keywords

-

Funding

  1. National Institutes of Health [EB001417, EB001980]

Ask authors/readers for more resources

The coupled system of the microwave cylindrical TE011 cavity and the TE01 delta dielectric modes has been analyzed in order to determine the maximum achievable resonator efficiency parameter of a dielectric inserted into a cavity, and whether this value can exceed that of a dedicated TE01 delta mode dielectric resonator. The frequency, Q value, and resonator efficiency parameter Lambda for each mode of the coupled system were calculated as the size of the dielectric was varied. Other output parameters include the relative field magnitudes and phases. Two modes are found: one with fields in the dielectric parallel to the fields in the cavity center and the other with antiparallel fields. Results closely match those from a computer program that solves Maxwell's equations by finite element methods. Depending on the relative natural resonance frequencies of the cavity and dielectric, one mode has a higher Q value and correspondingly lower Lambda than the other. The mode with the higher Q value is preferentially excited by a coupling iris or loop in or near the cavity wall. However, depending on the frequency separation between modes, either can be excited in this way. A relatively narrow optimum is found for the size of the insert that produces maximum signal for both modes simultaneously. It occurs when the self-resonance frequencies of the two resonators are nearly equal. The maximum signal is almost the same as that of the dedicated TE01 delta mode dielectric resonator alone, Lambda congruent to 40 G/W-1/2 at X-band for a KTaO3 crystal. The cavity is analogous to the second stage of a two-stage coupler. In general, there is no electron paramagnetic resonance (EPR) signal benefit by use of a second stage. However, there is a benefit of convenience. A properly designed sample-mounted resonator inserted into a cavity can give EPR signals as large as what one would expect from the dielectric resonator alone. (C) 2008 American Institute of Physics. [DOI: 10.1063/1.2976033]

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available