Determination of peanut allergens in cereal-chocolate-based snacks: metal-tag inductively coupled plasma mass spectrometry immunoassay versus liquid chromatography/electrospray ionization tandem mass spectrometry

Journal

RAPID COMMUNICATIONS IN MASS SPECTROMETRY
Volume 22, Issue 6, Pages 807-811

Publisher

WILEY
DOI: 10.1002/rcm.3427

Keywords

-

Ask authors/readers for more resources

A comparison of two methods for the identification and determination of peanut allergens based on europium (Eu)-tagged inductively coupled plasma mass spectrometry (ICP-MS) immunoassay and on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with a triple quadrupole mass analyzer was carried out on a complex food matrix like a chocolate rice crispy-based snack. The LC/MS/MS method was based on the determination of four different peptide biomarkers selective for the Ara h2 and Ara h3/4 peanut proteins. The performance of this method was compared with that of a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) method with ICP-MS detection of the metal used to tag the antibody for the quantitative peanut protein analysis in food. The limit of detection (LOD) and quantitation of the ICP-MS immunoassay were 2.2 and 5 mu g peanuts g(-1) matrix, respectively, the recovery ranged from 86 +/- 18% to 110 +/- 4% and linearity was proved in the 5-50 mu g g(-1) range. The LC/MS/MS method allowed us to obtain LODs of 1 and 5 mu g protein g(-1) matrix for Ara h3/4 and Ara h2, respectively, thus obtaining significantly higher values with respect to the ELISA ICP-MS method, taking into account the different expression for concentrations. Linearity was established in the 10-200 mu g g(-1) range of peanut proteins in the food matrix investigated and good precision (RSD < 10%) was demonstrated. Both the two approaches, used for screening or confirmative purposes, showed the power of mass spectrometry when used as a very selective detector in difficult matrices even if some limitations still exist, i.e. matrix suppression in the LC/ESI-MS/MS procedure and the change of the Ag/Ab binding with matrix in the ICP-MS method. Copyright (C) 2008 John Wiley & Sons, Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available