4.7 Article

Assessment of Regional Lung Function with Multivolume 1H MR Imaging in Health and Obstructive Lung Disease: Comparison with 3He MR Imaging

Journal

RADIOLOGY
Volume 273, Issue 2, Pages 580-590

Publisher

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.14132470

Keywords

-

Funding

  1. National Institutes of Health
  2. Severe Asthma Research Program
  3. Asthmatx/Boston Scientific
  4. IPS/Holaira
  5. Genentech
  6. Boston Scientific
  7. Amgen
  8. Caption/Cephalon/Teva
  9. Medimmune
  10. Merck
  11. Novartis
  12. GSK
  13. Sanofi Aventis
  14. Vectura
  15. Next Bio
  16. KaloBios

Ask authors/readers for more resources

Purpose: To introduce a method based on multivolume proton (hydrogen [H-1]) magnetic resonance (MR) imaging for the regional assessment of lung ventilatory function, investigating its use in healthy volunteers and patients with obstructive lung disease and comparing the outcome with the outcome of the research standard helium 3 (He-3) MR imaging. Materials and Methods: The institutional review board approved the HIPAA-compliant protocol, and informed written consent was obtained from each subject. Twenty-six subjects, including healthy volunteers (n = 6) and patients with severe asthma (n = 11) and mild (n = 6) and severe (n = 3) emphysema, were imaged with a 1.5-T whole-body MR unit at four lung volumes (residual volume [RV], functional residual capacity [FRC], 1 L above FRC [FRC+1 L], total lung capacity [TLC]) with breath holds of 10-11 seconds, by using volumetric interpolated breath-hold examination. Each pair of volumes were registered, resulting in maps of H-1 signal change between the two lung volumes. He-3 MR imaging was performed at FRC+1 L by using a two-dimensional gradient-echo sequence. H-1 signal change and He-3 signal were measured and compared in corresponding regions of interest selected in ventral, intermediate, and dorsal areas. Results: In all volunteers and patients combined, proton signal difference between TLC and RV correlated positively with He-3 signal (correlation coefficient R-2 = 0.64, P < .001). Lower (P < .001) but positive correlation results from H-1 signal difference between FRC and FRC+1 L (R-2 = 0.44, P < .001). In healthy volunteers, H-1 signal changes show a higher median and interquartile range compared with patients with obstructive disease and significant differences between nondependent and dependent regions. Conclusion: Findings in this study demonstrate that multivolume H-1 MR imaging, without contrast material, can be used as a biomarker for regional ventilation, both in healthy volunteers and patients with obstructive lung disease. (C) RSNA, 2014

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available