4.7 Article

A new high-background-rejection dark matter Ge cryogenic detector

Journal

PHYSICS LETTERS B
Volume 681, Issue 4, Pages 305-309

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.physletb.2009.10.036

Keywords

Dark Matter; Cryogenic Ge detectors; Coplanar grid; Surface event rejection

Funding

  1. Agence Nationale pour la Recherche [ANR-06-BLAN-0376-01]
  2. Agence Nationale de la Recherche (ANR) [ANR-06-BLAN-0376] Funding Source: Agence Nationale de la Recherche (ANR)

Ask authors/readers for more resources

A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy beta. approaching 10(5). This opens the road to investigate the range beyond 10(-8) pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-toil cryogenic detector mass. (C) 2009 Elsevier B.V. All rights reserved.