Computer-aided detection (CAD) has been shown to increase the sensitivity for detection of pulmonary nodules in adults. This study reports initial findings utilizing a CAD system for the detection of pediatric pulmonary nodules. To assess the performance of CAD and pediatric radiologists in the detection of pediatric pulmonary nodules. CT scans from a series of pediatric patients with known primary tumors and lung nodules were analyzed by four radiologists and a commercially available CAD system. IRB approval was obtained. Sensitivities were calculated for detection according to nodule size and location. In 24 children (age 3-18 years) 173 nodules were identified. Overall the sensitivity of CAD was 34%, but the sensitivity of CAD for detection of nodules 4.0 mm or larger was 80%. Overall radiologist sensitivity ranged from 68% to 79%. There were 0.9 CAD false-positives and 0.3-2.4 radiologist false-positives per study. CAD in our pediatric oncology patients had good sensitivity for detection of lung nodules 4 mm and larger with a low number of false-positives. However, the sensitivity was considerably less for nodules smaller than 4 mm.