4.5 Article

Proximal hip geometry and hip fracture risk assessment in a Korean population

Journal

OSTEOPOROSIS INTERNATIONAL
Volume 22, Issue 3, Pages 803-807

Publisher

SPRINGER LONDON LTD
DOI: 10.1007/s00198-010-1301-7

Keywords

Fracture risk assessment; Hip fracture; Proximal femoral geometry

Funding

  1. National Research Foundation of Korea [2009-0078183]
  2. National Research Foundation of Korea [2009-0078183] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

The association between proximal femoral geometry and hip fracture risk were investigated. The risk of intertrochanteric fractures increased 1.64-fold and 2.32-fold with 1 standard deviation (sd) increase of hip axis length and neck-shaft angle, respectively, while the risk of femur neck fracture 2.03-fold with 1 sd decrease in femoral head offset. The purpose of this study was to determine the association between proximal femoral geometry (PFG) and the risk of hip fracture in femur neck (FN) and intertrochanteric (IT) fractures in a Korean population. The study included 151 patients (57 patients with IT fractures, 43 patients with FN fractures, and 51 control patients). Data on BMD, PFG parameters (hip axis length [HAL], neck-shaft angle [NSA], neck length, femoral head offset, neck diameter, shaft diameter (SD), and demographics [age, gender, height, and body weight]) were collected. Descriptive statistics and odds ratios of PFG parameters corrected with demographic variables were obtained using logistic regressions. HAL (p = 0.046) and NSA (p = 0.003) were significantly greater in the patients with IT fracture than in the control patients, while neither parameter was significantly greater in patients with FN fractures than the control patients. The femoral head offset was significantly shorter in the patients with FN fractures (p = 0.003) compared with the control patients. In patients with IT fractures, the fracture risk increased 1.64-fold (p = 0.048) with a 1 sd increase of the HAL, while it increased 2.32-fold (p = 0.003) with a 1 sd increase of the NSA. In FN fractures, the fracture risk increased 2.03-fold (p = 0.012) with a 1 sd decrease in femoral head offset. Our study showed that some PFG parameters as well as BMD values predict hip fractures in a Korean population, and their evaluation may be useful in the understanding of the biomechanics of hip fractures.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available