4.4 Article

Inter- and intra-rater reproducibility of automated and integrated pressure-flow analysis of esophageal pressure-impedance recordings

Journal

NEUROGASTROENTEROLOGY AND MOTILITY
Volume 26, Issue 2, Pages 168-175

Publisher

WILEY-BLACKWELL
DOI: 10.1111/nmo.12246

Keywords

dysphagia; electrical impedance; esophageal manometry; esophagus; reproducibility

Funding

  1. Sandhill Scientific Inc.

Ask authors/readers for more resources

BackgroundAutomated impedance manometry pressure-flow analysis (AIM analysis) determines pressure measurements relative to bolus flow and has to date shown subtle variations in esophageal motility in relation to dysphagia. In this study, we assessed intra- and inter-rater reproducibility of AIM metrics derived using purpose designed software. MethodsFifty patients referred for evaluation of gastro-esophageal reflux symptoms (33 men, age 521.9years) underwent combined high-resolution impedance manometry and completed a dysphagia questionnaire. From 10 liquid and 10 viscous swallows, a subset of four swallows (two saline and two viscous) was systematically selected from each patient for manual and AIMplot analysis, which was performed twice by five observers (two experts, three non-experts). Intra- and inter-rater agreement were determined using intraclass correlation coefficients. Key ResultsAIMplot-based analysis showed high intra-rater and inter-rater reproducibility for all metrics (mean ICCs of 0.95 and 0.94, respectively). Reproducibility of metrics derived for liquid and viscous did not differ (ICCs of 0.96 and 0.91 for liquid and viscous, respectively). In addition, metrics derived by experts had an equivalent level of reproducibility compared to non-experts (ICCs of 0.96 and 0.94, respectively). Variables that could be derived with commercial software (ManoView) correlated highly with variables from AIMplot-based analysis, such as 4-s integrated relaxation pressure (r=0.85) and the 20-mmHg isobaric contour defect (r=0.92). Conclusions & InferencesEsophageal AIM analysis is highly reproducible, independent of an observer's level of experience in esophageal motility. Therefore, AIM analysis produces data that are reliable for clinical and research purposes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available