Addendum to the AAPMˈs TG-51 protocol for clinical reference dosimetry of high-energy photon beams
Published 2014 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Addendum to the AAPMˈs TG-51 protocol for clinical reference dosimetry of high-energy photon beams
Authors
Keywords
-
Journal
MEDICAL PHYSICS
Volume 41, Issue 4, Pages 041501
Publisher
Wiley
Online
2014-03-13
DOI
10.1118/1.4866223
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Ion recombination corrections of ionization chambers in flattening filter-free photon radiation
- (2017) Yuenan Wang et al. Journal of Applied Clinical Medical Physics
- Ion recombination correction factors (Pion) for Varian TrueBeam high-dose-rate therapy beams
- (2017) Stephen F. Kry et al. Journal of Applied Clinical Medical Physics
- Temperature dependence of cavity ionization chamber response
- (2013) Chul-Young Yi et al. METROLOGIA
- Consistency in reference radiotherapy dosimetry: resolution of an apparent conundrum when60Co is the reference quality for charged-particle and photon beams
- (2013) Pedro Andreo et al. PHYSICS IN MEDICINE AND BIOLOGY
- Beam quality conversion factors for parallel-plate ionization chambers in MV photon beams
- (2012) B. R. Muir et al. MEDICAL PHYSICS
- Calculation of beam quality correction factors for various thimble ionization chambers using the Monte Carlo code PENELOPE
- (2012) Fabián Erazo et al. Physica Medica-European Journal of Medical Physics
- The effect of air cavity size in cylindrical ionization chambers on the measurements in high-energy radiotherapy photon beams—an experimental study
- (2012) John Swanpalmer et al. PHYSICS IN MEDICINE AND BIOLOGY
- The central electrode correction factor for high-Z electrodes in small ionization chambers
- (2011) B. R. Muir et al. MEDICAL PHYSICS
- Measured and Monte Carlo calculated k Q factors: Accuracy and comparison
- (2011) B. R. Muir et al. MEDICAL PHYSICS
- Experimental investigation of the effect of air cavity size in cylindrical ionization chambers on the measurements in60Co radiotherapy beams
- (2011) John Swanpalmer et al. PHYSICS IN MEDICINE AND BIOLOGY
- Experimental determination of the effective point of measurement for various detectors used in photon and electron beam dosimetry
- (2011) Hui Khee Looe et al. PHYSICS IN MEDICINE AND BIOLOGY
- Ion recombination for ionization chamber dosimetry in a helical tomotherapy unit
- (2010) H. Palmans et al. MEDICAL PHYSICS
- Monte Carlo calculations of kQ, the beam quality conversion factor
- (2010) B. R. Muir et al. MEDICAL PHYSICS
- Measurement of ionization chamber absorbed dose kQ factors in megavoltage photon beams
- (2010) Malcolm R. McEwen MEDICAL PHYSICS
- Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors
- (2010) J Wulff et al. PHYSICS IN MEDICINE AND BIOLOGY
- A method to improve accuracy and precision of water surface identification for photon depth dose measurementsa)
- (2009) J. D. Ververs et al. MEDICAL PHYSICS
- Effective point of measurement of thimble ion chambers in megavoltage photon beams
- (2009) Frédéric Tessier et al. MEDICAL PHYSICS
- Task Group 142 report: Quality assurance of medical acceleratorsa)
- (2009) Eric E. Klein et al. MEDICAL PHYSICS
- Photon absorbed dose standards
- (2009) Jan Seuntjens et al. METROLOGIA
- The determination of beam quality correction factors: Monte Carlo simulations and measurements
- (2009) D M González-Castaño et al. PHYSICS IN MEDICINE AND BIOLOGY
- The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy
- (2009) Bruce A Faddegon et al. PHYSICS IN MEDICINE AND BIOLOGY
- Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration
- (2008) Pablo Castro et al. Journal of Applied Clinical Medical Physics
- Relationship between %dd(10)x and stopping-power ratios for flattening filter free accelerators: A Monte Carlo study
- (2008) Guoming Xiong et al. MEDICAL PHYSICS
- Efficiency improvements for ion chamber calculations in high energy photon beams
- (2008) J. Wulff et al. MEDICAL PHYSICS
- Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM
- (2008) Indra J. Das et al. MEDICAL PHYSICS
- The effective point of measurement of ionization chambers and the build-up anomaly in MV x-ray beams
- (2008) M. R. McEwen et al. MEDICAL PHYSICS
- The characterization of unflattened photon beams from a 6 MV linear accelerator
- (2008) Jason Cashmore PHYSICS IN MEDICINE AND BIOLOGY
- PENLINAC: extending the capabilities of the Monte Carlo code PENELOPE for the simulation of therapeutic beams
- (2008) M L Rodríguez PHYSICS IN MEDICINE AND BIOLOGY
- Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams
- (2008) J Wulff et al. PHYSICS IN MEDICINE AND BIOLOGY
Add your recorded webinar
Do you already have a recorded webinar? Grow your audience and get more views by easily listing your recording on Peeref.
Upload NowAsk a Question. Answer a Question.
Quickly pose questions to the entire community. Debate answers and get clarity on the most important issues facing researchers.
Get Started