A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy
Published 2011 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy
Authors
Keywords
-
Journal
MEDICAL PHYSICS
Volume 38, Issue 12, Pages 6763-6774
Publisher
Wiley
Online
2011-12-01
DOI
10.1118/1.3664007
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Dosimetric evaluation of Plastic Water Diagnostic Therapy
- (2017) Ramani Ramaseshan et al. Journal of Applied Clinical Medical Physics
- Angular dose dependency of MatriXX TM and its calibration
- (2017) Luciant D. Wolfsberger et al. Journal of Applied Clinical Medical Physics
- Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light-dominated situations
- (2011) Mathieu Guillot et al. MEDICAL PHYSICS
- Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge
- (2011) P Z Y Liu et al. PHYSICS IN MEDICINE AND BIOLOGY
- Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector
- (2010) Frédéric Lacroix et al. MEDICAL PHYSICS
- SU-GG-T-329: Gafgui: An Open-Source Project for Radiochromic Film Dosimetry
- (2010) H Bouchard et al. MEDICAL PHYSICS
- SU-GG-T-328: Dosimetric Performance of the Plastic Scintillation Detector for Radiosurgery Quality Assurance
- (2010) J Gagnon et al. MEDICAL PHYSICS
- Characterization and clinical evaluation of a novel IMRT quality assurance system
- (2009) Ramaswamy Sadagopan et al. Journal of Applied Clinical Medical Physics
- Calibration of a novel four-dimensional diode array
- (2009) Guanghua Yan et al. MEDICAL PHYSICS
- On the characterization and uncertainty analysis of radiochromic film dosimetry
- (2009) Hugo Bouchard et al. MEDICAL PHYSICS
- A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization
- (2009) Frédéric Lacroix et al. MEDICAL PHYSICS
- The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification
- (2009) V. Collomb-Patton et al. MEDICAL PHYSICS
- Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I'mRT MatriXX-–a feasibility study
- (2009) Barbara Dobler et al. PHYSICS IN MEDICINE AND BIOLOGY
- Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applicationsa)
- (2008) Fréderic Lacroix et al. MEDICAL PHYSICS
- The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Čerenkov discrimination methods
- (2008) A-M. Frelin et al. MEDICAL PHYSICS
- Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator
- (2008) Louis Archambault et al. MEDICAL PHYSICS
Add your recorded webinar
Do you already have a recorded webinar? Grow your audience and get more views by easily listing your recording on Peeref.
Upload NowAsk a Question. Answer a Question.
Quickly pose questions to the entire community. Debate answers and get clarity on the most important issues facing researchers.
Get Started