4.4 Article

Simulation of longitudinal stent deformation in a patient-specific coronary artery

Journal

MEDICAL ENGINEERING & PHYSICS
Volume 36, Issue 4, Pages 467-476

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.medengphy.2014.02.004

Keywords

Longitudinal stent deformation; Stents; Stent malapposition; Finite element analysis; Patient specific model

Funding

  1. Medtronic
  2. Haemonetics
  3. Boston Scientific
  4. St. Jude Medical
  5. Abbott Vascular
  6. Lilly/DS
  7. Engineering and Physical Sciences Research Council [1158087] Funding Source: researchfish

Ask authors/readers for more resources

In percutaneous coronary intervention (PCI), stent malapposition is a common complication often leading to stent thrombosis (ST). More recently, it has also been associated with longitudinal stent deformation (LSD) normally occurring through contact of a post balloon catheter tip and the protruding malapposed stent struts. The aim of this study was to assess the longitudinal integrity of first and second generation drug eluting stents in a patient specific coronary artery segment and to compare the range of variation of applied loads with those reported elsewhere. We successfully validated computational models of three drug-eluting stent designs when assessed for longitudinal deformation. We then reconstructed a patient specific stenosed right coronary artery segment by fusing angiographic and intravascular ultrasound (IVUS) images from a real case. Within this model the mechanical behaviour of the same stents along with a modified device was compared. Specifically, after the deployment of each device, a compressive point load of 0.3 N was applied on the most malapposed strut proximally to the models. Results indicate that predicted stent longitudinal strength (i) is significantly different between the stent platforms in a manner consistent with physical testing in a laboratory environment, (ii) shows a smaller range of variation for simulations of in vivo performance relative to models of in vitro experiments, and (iii) the modified stent design demonstrated considerably higher longitudinal integrity. Interestingly, stent longitudinal stability may differ drastically after a localised in vivo force compared to a distributed in vitro force. (C) 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available