4.5 Article

In Vivo 31P MR Spectroscopic Imaging of the Human Prostate at 7 T: Safety and Feasibility

Journal

MAGNETIC RESONANCE IN MEDICINE
Volume 68, Issue 6, Pages 1683-1695

Publisher

WILEY-BLACKWELL
DOI: 10.1002/mrm.24175

Keywords

prostate; P-31 MR spectroscopic imaging; endorectal P-31 coil; safety validation

Funding

  1. European Research Council under the European Community [243115]
  2. Dutch Cancer Society [KUN 2007/3971]
  3. German Federal Ministry of Education and Research (Bundesministerium fur Bildung und Forschung) [BMBF 01EZ0716]

Ask authors/readers for more resources

P-31 MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D P-31 MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a P-31 endorectal coil was developed and combined with an eight-channel H-1 body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and B-1(+) measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the P-31 endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel H-1 array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the H-1 array coil was allowed. For transmitting with the P-31 endorectal coil, our safety limit of less than 1 degrees C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D P-31 MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm(3). The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer. Magn Reson Med 68:1683-1695, 2012. (C) 2012 Wiley Periodicals, Inc.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available