4.4 Article

Phosphorus migration analysis using synchrotron radiation in soil treated with Brazilian granular fertilizers

Journal

APPLIED RADIATION AND ISOTOPES
Volume 105, Issue -, Pages 233-237

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.apradiso.2015.08.036

Keywords

Soil; Fertilizers; Phosphorus concentration; TXRF

Funding

  1. Brazilian National Synchrotron Light Laboratory [XAFS1-14453]

Ask authors/readers for more resources

The aim of this study was to evaluate the phosphorus (P) mobility in a tropical Brazilian soil type red Oxisol treated with three different forms of granular fertilizer. Total Reflection X-Ray Fluorescence (TXRF) was applied to determine the concentration of P at different distances from granular fertilizer application point The results showed that most of the P from fertilizers tends to concentrate in a region of up to 10 mm around the place of the fertilizer deposition. (C) 2015 Published by Elsevier Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

Article Spectroscopy

Laser-Induced Breakdown Spectroscopy Associated with Multivariate Analysis Applied to Discriminate Fertilizers of Different Nature

G. S. Senesi, R. A. Romano, B. S. Marangoni, G. Nicolodelli, P. R. Villas-Boas, V. M. Benites, D. M. B. P. Milori

JOURNAL OF APPLIED SPECTROSCOPY (2017)

Article Multidisciplinary Sciences

Transitions to sustainable management of phosphorus in Brazilian agriculture

Paul J. A. Withers, Marcos Rodrigues, Amin Soltangheisi, Teotonio S. de Carvalho, Luiz R. G. Guilherme, Vinicius de M. Benites, Luciano C. Gatiboni, Djalma M. G. de Sousa, Rafael de S. Nunes, Ciro A. Rosolem, Fernando D. Andreote, Adilson de Oliveira, Edson L. M. Coutinho, Paulo S. Pavinato

SCIENTIFIC REPORTS (2018)

Article Soil Science

Agronomic effectiveness of a granular poultry litter-derived organomineral phosphate fertilizer in tropical soils: Soil phosphorus fractionation and plant responses

Joaquim Jose Frazao, Vinicius de Melo Benites, Joao Victor Schiavon Ribeiro, Vitor Mateus Pierobon, Jose Lavres

GEODERMA (2019)

Article Materials Science, Ceramics

The effect of different ceramic materials to improve hardness of organomineral fertilizer granules

Carla O. Nascimento, Bianca B. Mattos, Rosana L. Fialho, Elaine C. M. Cabral-Albuquerque, Vinicius M. Benites

INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY (2020)

Article Chemistry, Physical

Study of composition and structure of demineralized bone using X-ray techniques

Erika Sales, Cristiane E. Ribeiro da Silva, Sonia Letichevsky, Ramon dos Santos, Luiz A. L. Teixeira Pinto, Claudio T. dos Santos, Luis Fernando de Oliveira, Roberto R. de Avillez, Mauricio Monteiro, Sidnei Paciornik, Marcelino dos Anjos

RADIATION PHYSICS AND CHEMISTRY (2020)

Article Agronomy

Polyhalite as a potassium and multinutrient source for plant nutrition

Sulian Junkes Dal Molin, Carla Oliveira Nascimento, Paulo Cesar Teixeira, Vinicius De Melo Benites

ARCHIVES OF AGRONOMY AND SOIL SCIENCE (2020)

Article Agricultural Engineering

Organomineral phosphate fertilization in millet in sandy soil

Maria D. M. Araujo, Henrique A. de Souza, Vinicius M. Benites, Roberto C. F. F. Pompeu, William Natale, Luiz F. C. Leite

REVISTA BRASILEIRA DE ENGENHARIA AGRICOLA E AMBIENTAL (2020)

Article Environmental Sciences

Phosphorus Diffusion and Agronomic Efficiency of Chicken Litter Organomineral Fertilizers Improved with Binder Materials

C. O. Nascimento, B. B. Mattos, S. J. Dal Molin, R. L. Fialho, E. C. M. Cabral-Albuquerque, V. M. Benites

Summary: The addition of materials to organomineral fertilizers can improve the mechanical strength of granules without affecting the dynamics of nutrient release and agronomic efficiency.

WASTE AND BIOMASS VALORIZATION (2021)

Article Green & Sustainable Science & Technology

A Poultry Litter-Derived Organomineral Phosphate Fertilizer Has Higher Agronomic Effectiveness Than Conventional Phosphate Fertilizer Applied to Field-Grown Maize and Soybean

Joaquim Jose Frazao, Vinicius de Melo Benites, Vitor Mateus Pierobon, Joao Victor Schiavon Ribeiro, Jose Lavres

Summary: Improper disposal of poultry litter can lead to water eutrophication due to its high phosphorus content. Recycling phosphorus from poultry litter to produce organomineral fertilizer reduces dependence on finite mineral phosphorus reserves and minimizes phosphorus losses from soil. Field experiments showed that applying granular poultry litter-derived organomineral fertilizer had similar effects on maize and soybean as single superphosphate, but demonstrated higher relative agronomic effectiveness based on shoot dry weight.

SUSTAINABILITY (2021)

Article Agronomy

Spectroscopic Investigation on the Effects of Biochar and Soluble Phosphorus on Grass Clipping Vermicomposting

Etelvino Henrique Novotny, Fabiano de Carvalho Balieiro, Ruben Auccaise, Vinicius de Melo Benites, Heitor Luiz da Costa Coutinho

Summary: This study evaluated the role of biochar in the composting and vermicomposting processes. The results showed that biochar improves the maturity of organic matter and reduces the negative effects on product quality.

AGRICULTURE-BASEL (2022)

Article Optics

Laser-induced breakdown spectroscopy and digital image data fusion for determination of the Al, Ca, Fe, Mg, and P in mineral fertilizer: overcome matrix effects in solid direct analysis

Diego Victor Babos, Jessica Franciele Kaminski Ramos, Gabriel Carlos Francisco, Vinicius De Melo Benites, Debora Marcondes Bastos Pereira Milori

Summary: This study evaluated the use of laser-induced breakdown spectroscopy (LIBS) and digital images for modeling the prediction of Al, Ca, Fe, Mg, and P contents in mineral fertilizer samples. The modeling strategies of matrix-matching calibration (MMC), multiple linear regression (MLR) using only LIBS data, and data fusion (LIBS + digital image) were compared. The results showed that data fusion had higher predictive capacity than MMC and MLR (LIBS data only), with a reduction in root mean square error (RMSE) values by 17% to 80%, indicating improved accuracy.

JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS (2023)

Article Environmental Sciences

CHARACTERIZATION AND INVESTIGATION OF CHICKEN LITTER AS A SOURCE OF PHOSPHORUS FOR FERTILIZERS

Carla Oliveira Nascimento, Sulian Junkes Dal Molin, Vinicius de Melo Benites, Elaine Christine de Magalhaes Cabral-Albuquerque, Rosana Lopes Fialho

Summary: The study characterized chicken litter produced in the Brazilian Midwest and conducted a greenhouse experiment to compare its agronomic efficiency with mineral fertilizer. The results showed that chicken litter was less efficient in terms of nutrition compared to mineral fertilizer, but the improvement in plant growth indicated its potential as a nutrient source when used properly.

ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL (2021)

Article Agriculture, Multidisciplinary

Phosphate fertilization with organomineral fertilizer on corn crops on a Rhodic Khandiudox with a high phosphorus content

Marco Andre Grohskopf, Juliano Corulli Correa, Dirceu Maximino Fernandes, Vinicius de Melo Benites, Paulo Cesar Teixeira, Caio Vilela Cruz

PESQUISA AGROPECUARIA BRASILEIRA (2019)

Proceedings Paper Instruments & Instrumentation

Sensitometric curve of radiographic films by X-ray fluorescence

E. A. S. Goncalves, D. F. Oliveira, M. J. Anjos, L. F. Oliveira, R. T. Lopes

9TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2017) (2018)

Article Agronomy

Losses of water, soil and nutrients by runoff after application of liquid swine manure in maize crop

June Faria Scherrer Menezes, Mariana Pina da Silva, Cleiton Gredson Sabin Benett, Vinicius de Melo Benites, Veridiana Cardozo Goncalves Cantao

REVISTA DE AGRICULTURA NEOTROPICAL (2018)

Article Chemistry, Inorganic & Nuclear

Primary standardization and half-life determination of 225Ac at NRC

R. Galea, K. Moore

Summary: In this study, the solution of 225Ac was standardized using the TDCR method. The counting efficiencies were calculated to be approximately 500% for the NRC TDCR system. The relative uncertainty for the activity concentration was determined to be 0.25%. The measured half-life of 225Ac was found to be consistent with previous measurements.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

A new determination of the 68Ga half-life and evaluation of literature data

N. C. Ramirez, S. M. Collins

Summary: In this paper, the authors determined the half-life of 68Ga using ionisation chambers measurements and HPGe gamma-ray spectrometry. They reviewed the current literature and identified possible causes of inconsistency within the dataset. The findings suggest that addressing these issues could lead to a significant improvement in future evaluations of the half-life.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Algorithm development for low level radioxenon 2D spectra analysis: A first case of study using spectral unmixing for a β-γ detector

C. P. Mano, C. Chapelle, Der Mesrobian Kabakian, H. Paradis, O. Delaune, L. Patryl

Summary: CEA/DAM is developing new beta-gamma measurement systems to enhance the reliability of the Comprehensive Nuclear Test Ban Treaty's verification regime. A new spectral unmixing algorithm for full-spectrum analysis was tested to improve analysis methods for nuclear activities with low statistics.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

A dose calculation algorithm for boron neutron capture therapy using convolution/superposition method

Junyoung Lee, Geunsub Kim, Hyegang Chang, Sangmin Lee, Sung-Joon Ye

Summary: The study applied the convolution/superposition method to calculate the dose distribution of boron neutron capture therapy and compared it with the Monte Carlo method. The results showed that the C/S method has a fast calculation speed and reasonable accuracy.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Radionuclide-free efficiency calibration of an HPGe detector using monochromatic photon beams calibrated with a cryogenic radiometer

Victor H. Elvira, Marie-Christine Lepy, Yves Menesguen, Stephanie Melhem

Summary: In this study, a cryogenic electrical-substitution radiometer was utilized for the primary calibration of monochromatic photon beams at a synchrotron facility, in order to determine the intrinsic efficiency and dead layer thickness of an HPGe detector. This calibration method allowed for the calculation of efficiency up to 55 keV, where the active thickness of the detector is not a determining factor. Geometrical efficiency was also determined through measurements of a radioactive source at various distances.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

The effect of geometrical parameters of skin brachytherapy patch source on depth dose distribution using Monte Carlo simulation

Ali Pashazadeh, Hamid Reza Baghani, Mostafa Robatjazi, Prajit Kadavil

Summary: This study investigated the effect of patch source geometric parameters on the depth dose distribution in skin tissue through Monte Carlo simulation. The results showed that increasing the source-to-skin distance, patch thickness, and patch diameter will reduce the depth dose distribution, with the source-to-skin distance having the most significant impact on dose gradient.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Measurement of fast-neutron activation cross section of the 109Ag (n,2n)108mAg reaction and its theoretical calculation of excitation function

Yueli Song, Fengqun Zhou, Yajuan Hao, Xiaopeng Zhang, Pengfei Ji, Yong Li

Summary: In this study, the cross section values of the 109Ag(n,2n)108mAg reaction at different neutron energies were measured using the activation technique and off-line gamma-ray spectrometry. The results were compared with experimental data, evaluated data from libraries, and theoretical values to validate their accuracy.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Development of a novel low-pressure scintillation cell with ZnS(Ag)-coated clapboard for Rn-220 measurement

Zhongkai Fan, Tao Hu, Xiangming Cai, Ruomei Xie, Haoxuan Li, Fengdi Qin, Shoukang Qiu, Yanliang Tan, Jian Shan

Summary: The high-precision measurement of Rn-220 is crucial for assessing and preventing thoron radiological hazards. By adding a ZnS(Ag)-coated clapboard, the issue of reduced Rn-220 concentrations due to decreased air pressure can be addressed, leading to improved detection efficiency. Experimental and simulation results provide valuable references for establishing the Rn-220 calibration factor.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Measurement and analysis of leakage neutron spectra from Lead slab samples with D-T neutrons

R. Han, Z. Chen, Y. Nie, B. Liu, G. Tian, X. Zhang, F. Shi, H. Sun, Z. Zhang, Y. Ding, X. Ruan, J. Ren, S. Zhang

Summary: The leakage neutron spectra of Lead samples were measured using a TOF technique, and MCNP simulations with different nuclear data libraries showed that JENDL-5.0 and JEFF-3.3 libraries have better agreement with experimental data. Differences in spectra mainly stem from variations in neutron reaction channels across the libraries, with ENDF/B-VIII.0 and CENDL-3.2 libraries being overestimated in certain energy ranges.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Radiation attenuation of boro-tellurite glasses for efficient shielding applications

Nissren Tamam, Maryam Al Huwayz, Z. A. Alrowaili, Norah Alwadai, Khadijah Mohammedsaleh Katubi, Mohammed S. Alqahtani, I. O. Olarinoye, M. S. Al-Buriahi

Summary: This study investigates the radiation shielding properties and radiation protection applications of borotellurite glasses. The results show that the addition of TeO2 can enhance the glass's ability to absorb photons and fast neutrons, and effectively suppress photon buildup. These glasses also exhibit exceptional gamma radiation and fast neutron moderating abilities, making them suitable for designing lead-free, transparent, and efficient radiation protection structures.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

On the accuracy of cross-section measurements of neutron-induced reactions using the activation technique with natural targets: The case of Ge at En=17.9 MeV

S. Chasapoglou, M. Kokkoris, R. Vlastou, M. Diakaki, V. Michalopoulou, A. Kalamara, G. Gkatis, A. Stamatopoulos, M. Axiotis, S. Harissopulos, A. Lagoyannis, M. I. Savva, T. Vasilopoulou, C. Lederer-Woods, N. Patronis, K. Kaperoni

Summary: This study investigated the accuracy and limitations of theoretical corrections in neutron-induced reactions on isotopically enriched Ge targets. Experimental cross-section measurements were conducted on several reactions using Ge-nat and isotopically enriched Ge targets. The results showed that the methodology using isotopically enriched targets provided accurate results without the need for theoretical corrections.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Optimization of an experimental TL protocol for discriminating the recombination pathways

P. G. Konstantinidis, G. S. Polymeris, E. Tsoutsoumanos, G. Kitis

Summary: This study investigates an altered version of an existing protocol to study the mechanisms and phenomena of stimulated luminescence. The protocol allows for the examination of recombination mechanisms and trapping parameters of the traps, as well as the observation of potential transitions between two different states.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Evaluating the broad neutron spectrum of ANIS

Quanzhi Yu

Summary: This study obtained the broad neutron spectrum of the Atmospheric Neutron Irradiation Spectrometer (ANIS) through Monte Carlo simulation and provided an analytic expression. By calculating the Single Error Rate (SER) and ratio, the reliability of the ANIS neutron spectrum was evaluated.

APPLIED RADIATION AND ISOTOPES (2024)

Article Chemistry, Inorganic & Nuclear

Decision threshold as a gauge of the measurement quality in gamma-ray spectrometric measurements

D. Glavic Cindro, M. Korun, T. Petrovic, B. Vodenik, B. Zorko

Summary: In gamma-ray spectrometric measurements, the decision threshold is determined by the observed value of the measurand. However, this dependence restricts its application to measurements with non-expressive indications. To address this issue, a recalculation of the decision thresholds based on the peak widths corresponding to expressive indications is proposed.

APPLIED RADIATION AND ISOTOPES (2024)