4.2 Article

A novel computational model for the hemodynamics of bileaflet mechanical valves in the opening phase

Publisher

SAGE PUBLICATIONS LTD
DOI: 10.1177/0954411915576944

Keywords

Computational fluid dynamics; vascular hemodynamics; turbulence modeling; shear stress transport; heart valve prostheses; boundary conditions; St Jude Medical valve; Reynolds averaging Navier-Stokes equation

Funding

  1. University of British Columbia
  2. NSERC/DG

Ask authors/readers for more resources

A powerful alternative means to study the hemodynamics of bileaflet mechanical heart valves is the computational fluid dynamics method. It is well recognized that computational fluid dynamics allows reliable physiological blood flow simulation and measurements of flow parameters. To date, in almost all of the modeling studies on the hemodynamics of bileaflet mechanical heart valves, a velocity (mass flow)-based boundary condition and an axisymmetric geometry for the aortic root have been assigned, which, to some extent, are erroneous. Also, there have been contradictory reports of the profile of velocity in downstream of leaflets, that is, in some studies, it is suggested that the maximum blood velocity occurs in the lateral orifice, and in some other studies, it is postulated that the maximum velocities in the main and lateral orifices are identical. The reported values for the peak velocities range from 1 to 3m/s, which highly depend on the model assumptions. The objective of this study is to demonstrate the importance of the exact anatomical model of the aortic root and the realistic boundary conditions in the hemodynamics of the bileaflet mechanical heart valves. The model considered in this study is based on the St Jude Medical valve in a novel modeling platform. Through a more realistic geometrical model for the aortic root and the St Jude Medical valve, we have developed a new set of boundary conditions in order to be used for the assessment of the hemodynamics of aortic bileaflet mechanical heart valves. The results of this study are significant for the design improvement of conventional bileaflet mechanical heart valves and for the design of the next generation of prosthetic valves.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available