4.6 Article

Intra-aortic balloon pump inserted through the subclavian artery: A minimally invasive approach to mechanical support in the ambulatory end-stage heart failure patient

Journal

JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY
Volume 144, Issue 4, Pages 951-955

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.jtcvs.2012.03.007

Keywords

-

Ask authors/readers for more resources

Objective: Intra-aortic balloon pumps are traditionally inserted through the femoral artery, limiting the patient's mobility. We used alternate approaches of intra-aortic balloon pump insertion to provide temporary and minimally invasive support for patients with decompensating, end-stage heart failure. The present study describes the outcomes with closed-chest, transthoracic intra-aortic balloon pumps by way of the subclavian artery. Methods: During a 3-year period, 20 patients underwent subclavian artery-intra-aortic balloon pump in the setting of end-stage heart failure. The balloon was inserted through a polytetrafluoroethylene graft sutured to the right subclavian artery in 19 patients (95%) and to the left subclavian artery in 1 patient (5%). The goal of support was to bridge to transplantation in 17 patients (85%) and bridge to recovery in 3 patients (15%). The primary outcome measure was death during subclavian artery-intra-aortic balloon pump support. The secondary outcomes included survival to the intended endpoint of bridge to transplantation/bridge to recovery, complications during subclavian artery-intra-aortic balloon pump support (eg, stroke, limb ischemia, brachial plexus injury, dissection, bleeding requiring reoperation, and device-related infection), emergent surgery for worsening heart failure, and ambulation during intra-aortic balloon pump support. Results: The duration of balloon support ranged from 3 to 48 days (mean, 17.3 +/- 13.1 days). No patients died during subclavian artery-intra-aortic balloon pump support. Of the 20 patients, 14 (70%) were successfully bridged to transplant or left ventricular-assist device. Two patients (10%) required emergent left ventricular-assist device for worsening heart failure. Conclusions: An intra-aortic balloon pump inserted through the subclavian artery is a simple, minimally invasive approach to mechanical support and is associated with limited morbidity and facilitates ambulation in patients with end-stage heart failure. (J Thorac Cardiovasc Surg 2012; 144: 951-5)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available