4.7 Review

Influence of Transcatheter Aortic Valve Replacement Strategy and Valve Design on Stroke After Transcatheter Aortic Valve Replacement

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 63, Issue 20, Pages 2101-2110

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2014.02.540

Keywords

CoreValve; Edwards Valve; stroke; TAVR; VARC

Ask authors/readers for more resources

Objectives The study undertook a systematic review to establish and compare the risk of stroke between the 2 widely used approaches (transfemoral [TF] vs. transapical [TA]) and valve designs (CoreValve, Medtronic, Minneapolis, Minnesota vs. Edwards Valve, Edwards Lifesciences, Irvine, California) for transcatheter aortic valve replacement (TAVR). Background There has been a rapid adoption and expansion in the use of TAVR. The technique is however far from perfect and requires further refinement to alleviate safety concerns that include stroke. Methods All studies reporting on the risk of stroke after TAVR were identified using an electronic search and pooled using established meta-analytical guidelines. Results 25 multicenter registries and 33 single-center studies were included in the analysis. There was no difference in pooled 30-day stroke post-TAVR between the TF and TA approach in multicenter (2.8% [95% confidence interval (CI): 2.4 to 3.4] vs. 2.8% [95% CI: 2.0 to 3.9]) and single-center studies (3.8% [95% CI: 3.1 to 4.6] vs. 3.4% [95% CI: 2.5 to 4.5]). Similarly, there was no difference in pooled 30-day stroke post TAVR between the CoreValve and Edwards Valve in multicenter (2.4% [95% CI: 1.9 to 3.2] vs. 3.0% [95% CI: 2.4 to 3.7]) and single-center studies (3.8% [95% CI: 2.8 to 4.9] vs. 3.2% [95% CI: 2.4 to 4.3]). There was a decline in stroke risk with experience and technological advancement. There was no difference in the outcome of 30-day stroke between TAVR and surgical aortic valve replacement. Conclusions Our findings suggest that the risk of 30-day stroke after TAVR is similar between the approaches and valve types. There has been a decline in stroke risk after TAVR with improvements in valve technology, patient selection, and operator experience. (c) 2014 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available