Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses
Published 2015 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses
Authors
Keywords
Deformation, Corrosion, Cobalt, Ceramics, Coatings, Titanium, Friction, Hip
Journal
PLoS One
Volume 10, Issue 8, Pages e0135517
Publisher
Public Library of Science (PLoS)
Online
2015-08-18
DOI
10.1371/journal.pone.0135517
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- Acute Delayed Infection: Increased Risk in Failed Metal on Metal Total Hip Arthroplasty
- (2014) Hernan A. Prieto et al. JOURNAL OF ARTHROPLASTY
- The Relation Between Titanium Taper Corrosion and Cobalt-Chromium Bearing Wear in Large-Head Metal-on-Metal Total Hip Prostheses
- (2014) F Witt et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Adverse Local Tissue Reaction Associated With a Modular Hip Hemiarthroplasty
- (2013) Michael R. Whitehouse et al. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
- Is Increased Modularity Associated With Increased Fretting and Corrosion Damage in Metal-On-Metal Total Hip Arthroplasty Devices?
- (2013) Genymphas B. Higgs et al. JOURNAL OF ARTHROPLASTY
- Taper Corrosion in Modular Hip Prostheses
- (2013) Bart J. Vundelinckx et al. JOURNAL OF ARTHROPLASTY
- Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip Replacements
- (2013) Richard B. Cook et al. JOURNAL OF ARTHROPLASTY
- Which Factors Determine the Wear Rate of Large-Diameter Metal-on-Metal Hip Replacements?
- (2013) A.J. Hart et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings
- (2013) Nicholas Bishop et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography
- (2013) Anna Panagiotidou et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Pseudotumor Associated With Metal-on-Polyethylene Total Hip Arthroplasty
- (2013) William F. Scully et al. ORTHOPEDICS
- Cobalt-Alloy Implant Debris Induce HIF-1α Hypoxia Associated Responses: A Mechanism for Metal-Specific Orthopedic Implant Failure
- (2013) Lauryn Samelko et al. PLoS One
- Friction in Total Hip Joint Prosthesis Measured In Vivo during Walking
- (2013) Philipp Damm et al. PLoS One
- Taper junction failure in large-diameter metal-on-metal bearings
- (2013) D. J. Langton et al. Bone & Joint Research
- High friction moments in large hard-on-hard hip replacement bearings in conditions of poor lubrication
- (2012) Nicholas E. Bishop et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales
- (2012) Alison J Smith et al. LANCET
- The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections
- (2012) M. Baxmann et al. MEDICAL ENGINEERING & PHYSICS
- Influence of assembly procedure and material combination on the strength of the taper connection at the head–neck junction of modular hip endoprostheses
- (2011) Annelie Rehmer et al. CLINICAL BIOMECHANICS
- Influence of material coupling and assembly condition on the magnitude of micromotion at the stem–neck interface of a modular hip endoprosthesis
- (2011) S.Y. Jauch et al. JOURNAL OF BIOMECHANICS
- The In Vivo Linear and Volumetric Wear of Hip Resurfacing Implants Revised for Pseudotumor
- (2011) Siôn Glyn-Jones et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Accelerating failure rate of the ASR total hip replacement
- (2011) D. J. Langton et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- 3D linear and volumetric wear measurement on artificial hip joints—Validation of a new methodology
- (2010) Mike Tuke et al. PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY
- Metal Sensitivity as a Cause of Groin Pain in Metal-on-Metal Hip Resurfacing
- (2008) Pat Campbell et al. JOURNAL OF ARTHROPLASTY
- Modes of Implant Failure After Hip Resurfacing: Morphological and Wear Analysis of 267 Retrieval Specimens
- (2008) Michael M Morlock et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Pseudotumours associated with metal-on-metal hip resurfacings
- (2008) H. Pandit et al. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME
- Influence of contaminants in the stem—ball interface on the static fracture load of ceramic hip joint ball heads
- (2008) B Weisse et al. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE
Find Funding. Review Successful Grants.
Explore over 25,000 new funding opportunities and over 6,000,000 successful grants.
ExploreDiscover Peeref hubs
Discuss science. Find collaborators. Network.
Join a conversation