Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 53, Issue 12, Pages 1075-1081

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2008.12.018

Keywords

cardiac resynchronization therapy; hemodynamic monitoring; pulmonary edema

Funding

  1. NHLBI NIH HHS [R01 HL068768-06, R01 HL 068768, R01 HL068768-08, R01 HL068768, R01 HL068768-07] Funding Source: Medline

Ask authors/readers for more resources

Objectives This study was designed to investigate the properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy system. Background The monitoring of CHF has relied mainly on right-side heart sensors. Methods Fifteen normal dogs underwent implantation of cardiac resynchronization therapy systems using standard leads. An additional left atrial (LA) pressure lead sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathoracic and intracardiac vectors, were measured through ring (r), coil (c), and device Can electrodes. Results Congestive heart failure developed in all animals after 2 to 4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LV(r)-Can, -17%; LV(r)-RVr, -15%; LV(r)-RAr, -11%; RV(r)-Can, -12%; RV(c)-Can, -7%; and RA(r)-Can, -5%. The LV(r)-Can vector reflected both the fastest and largest change in impedance in comparison with vectors employing only right-side heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure. Conclusions Impedance, acquired by different lead electrodes, has variable responses to CHF. Impedance vectors employing an LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients. (J Am Coll Cardiol 2009;53:1075- 81) c 2009 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available