4.2 Article

Evaluation of a Novel Reverse Thermosensitive Polymer for Use in Microvascular Surgery

Journal

JOURNAL OF RECONSTRUCTIVE MICROSURGERY
Volume 25, Issue 1, Pages 69-76

Publisher

THIEME MEDICAL PUBL INC
DOI: 10.1055/s-0028-1104556

Keywords

Microvascular clamps; reverse thermosensitive polymers; poloxamer 407; hemostasis; endothelial injury

Categories

Ask authors/readers for more resources

Microvascular clamps have several potential shortcomings, including the risk of vessel injury. LeGoo((TM)) a novel reverse thermosensitive polymer (Pluromed Inc., Woburn, MA), is investigated as a substitute to vascular clamping in a microsurgical model and the technical details are described. Femoral vessels of Sprague Dawley rats were used to evaluate the usefulness of this polymer for performing end-to-end arterioarterial (AA), venovenous (VV), and end-to-side arteriovenous (AV) microvascular anastomoses. The ability to obtain and maintain hemostasis was assessed. Secondary endpoints, including polymer volume, concentration, temperature, Infusion technique, ability to reinfuse, blood vessel stenting effect, polymer dissolution characteristics, and reestablishment of flow, were also noted. Initial hemostasis occurred in every case. Mean duration of efficacy (hemostasis),after initial injection was 1.7.8 minutes (4 minutes to 44.5 minutes) for AA anastomoses and 31.8 minutes (13 minutes to 46 minutes) for VV anastomoses. Mean volume of polymer initially injected was 0.11 mL (0.01. mL to 0.20 mL) and 0.07 mL (0.06 mL to 0.10 mL) for AA and AV arteries, respectively, and 0.14 rnL (0.10 mL to 0.20 mL) and 0.20 mL (0.15 mL to 0.27 mL) for VV and AV veins. Use of LeGoo in veins was clearly superior to arterial use with regard to the technical aspects of injecting LeGoo and reestablishing hemostasis, as well as greater vessel stenting effect and less vessel retraction. This novel polymer showed promise for its ability to allow for hemostasis while performing microvascular anastomoses. Improvements were made with regard to injection techniques, appropriate volumes, ability to reliably determine gel plug dissolution, and final vessel patency. Preliminary results demonstrate that this polymer may be a viable substitute for microvascular clamps.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available